13
10. After entering the exact value, press the NET/GROSS key to save the value. The screen
displays “dA_xx” where ‘xx’ is the current day of the month, e.g. “14”. One digit will be flash-
ing.
11. Use the four directional keys to adjust the displayed value to the actual day value. Increase
the flashing digit by pressing the UNITS key. Decrease the flashing digit by pressing the
ZERO/OFF key. Pressing the TARE key or the ON/PRINT key will change the position of
the flashing digit.
12. After entering the exact value, press the NET/GROSS key to save the value. The screen
displays “n¬_xx” where ‘xx’ is the current month of the year, e.g. “02”. One digit will be flash-
ing.
13. Use the four directional keys to adjust the displayed value to the actual month value. In-
crease the flashing digit by pressing the UNITS key. Decrease the flashing digit by pressing
the ZERO/OFF key. Pressing the TARE key or the ON/PRINT key will change the position
of the flashing digit.
14. After entering the exact value, press the NET/GROSS key to save the value. The screen
displays “yE_xx” where ‘xx’ is the current month of the year, e.g. “11”. One digit will be flash-
ing.
15. Use the four directional keys to adjust the displayed value to the actual year value. Increase
the flashing digit by pressing the UNITS key. Decrease the flashing digit by pressing the
ZERO/OFF key. Pressing the TARE key or the ON/PRINT key will change the position of
the flashing digit.
16. After entering the exact value, press the NET/GROSS key to save the value and revert back
up to the parameter level, e.g. ”A 20”.
17. In order to save all parameter settings, it is imperative to exit all menus in the following
manner: At the parameter level, press the UNITS (up) key twice (two times) to exit the User
Menu. The indicator displays ‘SAvE’ and then automatically powers off.
Set Point Control (RELAY OPTION)
This mode requires an optional relay board
.
This mode of operation is enabled by setting F30 to
“6” in the Setup Menu (see separate installer’s guide for more information).
The mode allows
you to add two ingredients to a mixture by weight or signal that a target weight has been
reached.
The weight of each ingredient to be added to the mixture is called a set point. The set points can
be entered from the front panel of the indicator.
Optional relay technical specifications: Type: Zettler AZ833-12DE
Coil voltage: 12VDC
Switched capacity: max. 30VDC/2A
The choice of relay application is made when the system is ordered and the application is se-
lected in the parameter menu (see separate installer’s guide for more information).
The instructions for use depend on which application is chosen.
Three different applications are possible;
1 – Unlatched target weight signal (one set point)
2 – Latched dosing/filling with manual start (two set points)
3 – Latched dosing/filling with auto start and (two set points)