XT500C DELUXE PROGRAMMABLE HEAT-PUMP THERMOSTAT

3

69-1404

Pub. No. 18-HD25D2-2

M14608

PRESS LOWER 
EDGE OF CASE 
TO LATCH.

ENGAGE TABS 
AT TOP OF 
THERMOSTAT 
AND WALLPLATE.

A.

B.

Using Thermostat Keys

The thermostat keys are used to:

Set current day and time,

Program times and setpoints for heating and cooling,

Temporarily override program temperatures,

Display present setting,

Configure Installer Setup,

Check Self-Test,

Display outdoor temperature (optional accessory),

Set the system operation, and

Set the fan operation.

See Fig. 6 for keypad explanation.

SETTINGS

System and Fan Settings

The system default setting is Heat and the fan default setting
is Auto. Use the System and Fan keys to change the settings.
See Figs. 7 and 8. The fan settings can be set for each
program period individually. The system selection is for all the
program periods.

System settings control the thermostat operation as follows:

Em Heat: Emergency heat relay is on continuously.

Thermostat cycles highest stage of heat. Cooling
system is off. Compressor is de-energized.

Heat: The thermostat controls the heating.
Off: Both the heating and cooling are off.
Cool: The thermostat controls the cooling.
Auto: The thermostat automatically changes between

heating and cooling operation, depending on the indoor
temperature.

Time

Set Program

System

Filter

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

INCREASE TEMPERATURE SETTING OR SCROLL 
FORWARD THROUGH INSTALLER SETUP OPTIONS

DECREASE 
TEMPERATURE
SETTING OR 
SCROLL BACKWARD 
THROUGH INSTALLER 
SETUP OPTIONS

DISPLAY
INFORMATION
SUCH AS PRESENT
SETTINGS 
AND OUTDOOR
TEMPERATURE

RETURN TO NORMAL
OPERATIONS

ENTER INDEFINITE 
OR TIMED HOLD MODE

SET CURRENT 
DAY AND TIME

SET CURRENT OR
PROGRAM DAY

CHANGE BETWEEN 
DAYLIGHT SAVINGS 
AND STANDARD TIME

INCREASE TIME 
SETTING OR SCROLL 
FORWARD THROUGH 
INSTALLER SETUP 
AND SYSTEM TEST

DECREASE TIME SETTING 
OR SCROLL BACKWARD 
THROUGH INSTALLER
SETUP AND SYSTEM TEST

COPY ONE 
PROGRAMMED DAY 
TO ANOTHER DAY

SET WAKE TIMES 
AND SETPOINTS

CHANGE BETWEEN 
HEATING AND 
COOLING SETPOINTS 

SET LEAVE TIMES
AND SETPOINTS

SET RETURN TIMES
AND SETPOINTS

SET SLEEP TIMES
AND SETPOINTS

M14609

SELECT SYSTEM 
OPERATION (EM HEAT,
HEAT, OFF, COOL, AUTO) 

SELECT FILTER 
EXPIRATION IN 
NUMBER OF DAYS 

SELECT FAN 
OPERATION 

Mounting Thermostat

1. Engage tabs at the top of the thermostat and wallplate.

See Fig. 5.

2. Press lower edge of case to close and latch.

NOTE:

To remove thermostat from wall, first pull out at
bottom of thermostat; remove top last.

Fig. 6. XT500C key locations and descriptions.

Fig. 5. Mounting thermostat on wallplate.

Summary of Contents for XT500C

Page 1: ...nd on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check...

Page 2: ...e is located near each terminal for identification WARNING Electrical Shock or Equipment Damage Hazard Can shock individuals or cause equipment damage Disconnect power before wiring to prevent electri...

Page 3: ...heating and cooling operation depending on the indoor temperature Time Set Program System Filter Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight...

Page 4: ...s on changing the default settings Table 2 Default Program Settings M17150 LED INDICATOR M14610 Aux Ht System Em Heat Em Ht FLAME DISPLAYS DURING CALL FOR HEAT AUX HT DISPLAYS WHEN SYSTEM CALLS FOR AD...

Page 5: ...of all the segments of the LCD IMPORTANT Only configurable numbers display Example Installer Setup Number 1 does not display because it is not configurable Review the factory settings in Table 3 and...

Page 6: ...system starts early so setpoint is reached by start of program period 1 Conventional recovery system starts recovery at programmed time Degree temp erature display 14 0 Temperature displays in F 1 Tem...

Page 7: ...essor 0 thru 15 Minimum number of minutes 0 thru 15 the compressor will be on during call for cool Temperature range stops in heating 34 85 Highest setpoint heating can be set to 55 to 85 Temperature...

Page 8: ...shes on the display until a key is pressed 2 Press Day until the current day displays NOTE Tapping the Set Current Day Time will change the time in one hour increments Press Time or Press Increase or...

Page 9: ...eat On Auto Off Cool Auto AM PM Hold for Heat Cool Repl Batt Recovery DST Tue Wed Thu Fri Sat Sun Days Temporary Setting Em Ht M14612 Key to Press Test Number Description Heating Equipment Self Test 1...

Page 10: ...and Comfort R is enabled display reads If the terminals are closed no displays Keyboard Operation Self Test 60 Time 60 7 Enter keyboard operation self test Temp 60 9 Increase test number displays Tem...

Page 11: ...ceed with troubleshooting Temperature display is incorrect Room temperature display has been reconfigured Enter Installer Setup number 37 and reconfigure the display Thermostat is configured for F or...

Page 12: ...g setpoint Set cooling setpoint to desired temperature Heating or cooling comes on momentarily and shuts off Heat or cool circuit is opening up or becoming high impedance Add resistor in parallel with...