background image

 

22-1889-01

Product Specifications

Model No. 

1

 

4TTR6018B1000A 4TTR6024B1000A 4TTR6030B1000A 4TTR6036B1000A

Electrical Data V/Ph/Hz

 

2

 

208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60

Min Cir Ampacity 

12 

19

Max Fuse Size (Amps) 

15 

15 

20 

30

Compressors CLIMATUFF

®

 CLIMATUFF

®

 CLIMATUFF

®

 CLIMATUFF

®  - 

SCROLL

No. Used - No. Stages 

1-1 

1-1 

1-1 

1-1

RL AMPS - LR AMPS 

6.4 - 38.6 

6.8 - 38.6 

9.1 - 57.8 

14.1 - 77

Outdoor Fan FL Amps 

0.74 

0.74 

0.93 

0.93

Fan 

HP 

1/8 1/8 1/5 1/5

Fan Dia (inches) 

23 

23 

27.6 

27.6

Coil 

Spine Fin™ 

Spine Fin™ 

Spine Fin™ 

Spine Fin™

Refrigerant 

R-410A 5/2-LB/OZ 6/3-LB/OZ 7/0-LB/OZ 7/4-LB/OZ

Line Size - (in.) O.D. Gas

 

3

 

5/8 3/4 3/4 3/4

Line Size - (in.) O.D. Liquid

 

3

 

3/8 3/8 3/8 3/8

Dimensions H x W x D (Crated) 

34 x 30.1 x 33 

34 x 30.1 x 33 

38.4 x 35.1 x 38.7 

42.4 x 35.1 x 38.7

Weight - Shipping 

200 

201 

234 

228

Weight - Net 

173 

174 

201 

193

Start 

Components 

YES YES YES  NO

Sound 

Enclosure 

YES YES YES YES

Compressor Sump Heat 

NO 

NO 

NO 

NO

Optional Accessories: 

4

Anti-short 

Cycle 

Timer 

TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A

Evaporator Defrost Control A/C 

AY28X079 

AY28X079 

AY28X079 

AY28X079

Rubber Isolator Kit 

BAYISLT101 

BAYISLT101 

BAYISLT101 

BAYISLT101

Crank Case Heater Kit 

BAYCCHT300 

BAYCCHT300 

BAYCCHT300 

BAYCCHT302

Hard Start Kit Scroll 

 

 

 

BAYKSKT260

Extreme Condition Mounting Kit 

BAYECMT023 

BAYECMT023 

BAYECMT004 

BAYECMT004

Snow Leg - Base & Cap 4" High 

BAYLEGS002 

BAYLEGS002 

BAYLEGS002 

BAYLEGS002

Snow Leg - 4" Extension 

BAYLEGS003 

BAYLEGS003 

BAYLEGS003 

BAYLEGS003

Seacoast 

Kit 

BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001

Refrigerant Lineset 

5

 TAYREFLN950  TAYREFLN7* 

TAYREFLN7* 

TAYREFLN7*

1

  Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.

2

  Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.

3

  Standard line lengths - 80'. Standard lift - 60' Suction and Liquid line.

 

For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0

. (

denotes latest revision) 

4

  For accessory description and usage, see page 5. 

5

  * = 15, 20, 25, 30, 40 and 50 foot lineset available.

General 

Data

Sound Power Level

Model

A-Weighted Sound 

Power Level [dB(A)]

Full Octave Sound Power [dB]

63 Hz

125 Hz

250 Hz

500 Hz

1000 Hz

2000 Hz

4000 Hz

8000 Hz

4TTR6018B1

75

51

61

65

74

74

72

61

51

4TTR6024B1

75

49

62

66

74

74

69

62

54

4TTR6030B1

75

54

69

72

78

76

72

64

54

4TTR6036B1

75

49

68

73

76

74

70

62

51

4TTR6042B1

75

49

69

74

77

75

70

62

51

4TTR6048B1

75

49

69

74

77

75

70

62

51

4TTR6049B1

74

70

70

65

64

62

56

49

42

4TTR6060B1

75

49

69

74

77

75

70

62

51

4TTR6061B1

75

68

70

67

68

64

56

53

48

Note: Rated in accordance with AHRI Standard 270-2008

Summary of Contents for XR16 4TTR6

Page 1: ...XR16 4TTR6 1 1 2 5 Tons Split System Cooling Product Data PUB NO 22 1889 01...

Page 2: ...rain weatherproof COMFORT R mode approved Glossy corrosion resistant finish Internal compressor high low pressure temperature protection 018 024 030 ship with start kit Liquid line filter drier Tarpau...

Page 3: ...2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 6 AHRI Standard Capacity Rating Conditions 6 Model Nomenclature 7 Electrical Data 8 Dimens...

Page 4: ...HT302 Hard Start Kit Scroll BAYKSKT260 Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 Snow Leg Base Cap 4 High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg 4 Extens...

Page 5: ...r TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A C AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT10...

Page 6: ...le power delivery commercial applications long lineset etc Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freezB up conditions Used fo...

Page 7: ...tronic Filter Draft Inducer Speeds 1 Single Speed 2 Two Speed V Variable Speed Gas Furnaces G A M 5 A 0 B 3 6 M 3 1 S A A Brand T Better G Good Product Type A Air Handler Product Tier 2 Good Entry Lev...

Page 8: ...8 22 1889 01 4TTR6018B 4TTR6024B 4TTR6030B Electrical Data Schematic Diagrams Printed from D157123P01 Rev 00...

Page 9: ...22 1889 01 9 4TTR6036B 4TTR6042B Electrical Data Schematic Diagrams Printed from D157124P01 Rev 00...

Page 10: ...10 22 1889 01 Electrical Data Schematic Diagrams Printed from D157125P01 Rev 00 4TTR6048B 4TTR6049B...

Page 11: ...22 1889 01 11 Electrical Data Schematic Diagrams Printed from D157177P01 Rev 00 4TTR6060B...

Page 12: ...12 22 1889 01 Electrical Data Schematic Diagrams Printed from D156975P01 4TTR6061B...

Page 13: ...22 1889 01 13 Electrical Data Schematic Diagrams 4TTR6061B continued...

Page 14: ...1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 4TTR6042B 4 1045 41 1 8 946 37 1 4 870 34 1 4 7 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 4TTR6048B 4 1147 45 1 8 946 37 1 4 870 34 1 4 7 8 3...

Page 15: ...system controls include condenser fan and compressor contac tor High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor The Climatuff...

Page 16: ...Trane www trane com 05 13 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice...