background image

22-1889-01 

7

Model 

Nomenclature

Refrigerant Type

2 = R-22

4 = R-410A

TRANE
Product Type

W = Split Heat Pump

T = Split Cooling

Product Family

Z = Leadership – Two Stage

X = Leadership

R = Replacement/Retail

B = Basic

A = Light Commercial

Family SEER

0 = 10 

3 = 13 

6 = 16

1 = 11 

4 = 14 

8 = 18

2 = 12 

5 = 15 

9 = 19

Split System Connections 1-6 Tons

0 = Brazed

Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply

1 = 200-230/1/60 or 208-230/1/60

3 = 200-230/3/60

4 = 460/3/60

Secondary Function
Minor Design Modifications
Unit Parts Identifier

Outdoor Units

4 T T R 6 0 3 6 B 1 0 0 0 A A

T   U   D   1   B   0   8   0   A   9   H   3   1   A   A

Furnace Configuration

TU = Upflow/Horizontal

TD = Downflow/Horizontal

Type

E = 80% Induced Draft Standard

D = 80% Induced Draft Premium

C = 90% Condensing Standard

X = 90% Condensing Premium

H = 95% Condensing Premium

Number of Heating Stages

1 = Single Stage

2 = Two Stage

M = Modulating

Major Design Change

Minor Design Change

Service Digit - Not Orderable

Heating Input in 1000’s (BTUH)

080 = 80,000 BTUH

Cabinet Width

A = 14.5" Cabinet Width

B = 17.5" Cabinet Width

C = 21.0" Cabinet Width

D = 24.5" Cabinet Width

Air Capacity for Cooling

Standard PSC  Variable Speed  High Efficiency

24 = 2 Tons 

V3 = 3 Tons 

H3 = 3 Tons

36 = 3 Tons 

V4 = 4 Tons 

H4 = 4 Tons

42 = 3.5 Tons 

V5 = 5 Tons 

H5 = 5 Tons

45 = 4 Tons

48 = 4 Tons

54 = 5 Tons

60 = 5 Tons

72 = 6 Tons

Voltage

9 = 115 Volts / 60 Hertz / Natural Gas

A = 115 Volts / 50 Hertz / Natural Gas

C = 115 Volts / Natural Gas with Communicating System Control

F = 115 Volts / Natural Gas with Integrated Electronic Filter

D = 115 Volts / Natural Gas with Communicating System Control and

  Integrated Electronic Filter

Draft Inducer Speeds

1  = Single Speed

2  = Two Speed

V = Variable Speed

Gas Furnaces

G   A   M   5   A   0   B   3   6   M   3   1   S   A   A

Brand

T  = Better

G = Good 

Product Type

A = Air Handler

Product Tier

2 = Good, Entry Level Feature Set

4 = Better, Retail Replacement Mid Effy.

5 = Better, Entry Level High Effy., Multi-Speed

7 = Best, Retail Replacement High Effy.,

  

Variable-Speed

8 = Best, Retail Ultimate High Effy., 

  

Variable-Speed

Major Design Change

Minor Design Change
Unit Parts Identifier

Airflow Type & Capability

S = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton)

M = Mid Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton)

H = High Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton)

V = High Effy Variable, 1-5 - nom. Tonnage (cfm/ton)

No Descriptor

0 = Air Handler / Coil

System Control Type

S = Standard - 24 VAC

C = CLII 13.8 VDC

Size (Footprint)

A = 17.5 x 21.5

B = 21.0 x 21.5

C = 23.5 x 21.5

Cooling Size: Air Handler or Coil

0-9  = AH Coil - 1000 BTU’s (18, 24, 30, 36, 42, 48, 60)

Power Supply

1 = 208-230/1/60

Convertability

M = Multi-poise 4-way

F = Upflow Front Return, 3-way

T = 3-way

Air Handler

4  T  X  C  B  0   3 6    A   C   3   H   C   A   A

Series

T = Premium 

(Heat Pump or Convertible Coil)

C = Standard 

(Cooling Only)

Refrigerant Type

4 = R-410A

Coil Design

X  = Direct Expansion Evaporator Coil

Coil Feature

C = Cased A Coil

A = Uncased A Coil

F = Cased Horizontal Flat Coil

Coil Width (Cased/Uncased)

A = 14.5" /13.3"

B = 17.5" / 16.3"

C = 21.0" / 19.8"

D = 24.5" / 23.3"

H = 10.5"

Refrigerant Line Coupling

0 = Brazed

Nominal Capacity in 1000's (BTUH)
Major Design Change
Efficiency

C = Standard

S = Hi Efficiency (derived from 10 SEER products)

Refrigerant Control

3 = TXV - Non-Bleed

Coil Circuitry

H = Heat Pump

C = Cooling

Airflow Configuration

A = Upflow Only

U = Upflow / Downflow

H = Horizontal Only

C = Convertible - Upflow, Downflow, Left or Right Airflow

Minor Design Change
Service Digit - Not Orderable

Heat Pump/

Cooling Coils

Summary of Contents for XR16 4TTR6

Page 1: ...XR16 4TTR6 1 1 2 5 Tons Split System Cooling Product Data PUB NO 22 1889 01...

Page 2: ...rain weatherproof COMFORT R mode approved Glossy corrosion resistant finish Internal compressor high low pressure temperature protection 018 024 030 ship with start kit Liquid line filter drier Tarpau...

Page 3: ...2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 6 AHRI Standard Capacity Rating Conditions 6 Model Nomenclature 7 Electrical Data 8 Dimens...

Page 4: ...HT302 Hard Start Kit Scroll BAYKSKT260 Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 Snow Leg Base Cap 4 High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg 4 Extens...

Page 5: ...r TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A C AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT10...

Page 6: ...le power delivery commercial applications long lineset etc Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freezB up conditions Used fo...

Page 7: ...tronic Filter Draft Inducer Speeds 1 Single Speed 2 Two Speed V Variable Speed Gas Furnaces G A M 5 A 0 B 3 6 M 3 1 S A A Brand T Better G Good Product Type A Air Handler Product Tier 2 Good Entry Lev...

Page 8: ...8 22 1889 01 4TTR6018B 4TTR6024B 4TTR6030B Electrical Data Schematic Diagrams Printed from D157123P01 Rev 00...

Page 9: ...22 1889 01 9 4TTR6036B 4TTR6042B Electrical Data Schematic Diagrams Printed from D157124P01 Rev 00...

Page 10: ...10 22 1889 01 Electrical Data Schematic Diagrams Printed from D157125P01 Rev 00 4TTR6048B 4TTR6049B...

Page 11: ...22 1889 01 11 Electrical Data Schematic Diagrams Printed from D157177P01 Rev 00 4TTR6060B...

Page 12: ...12 22 1889 01 Electrical Data Schematic Diagrams Printed from D156975P01 4TTR6061B...

Page 13: ...22 1889 01 13 Electrical Data Schematic Diagrams 4TTR6061B continued...

Page 14: ...1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 4TTR6042B 4 1045 41 1 8 946 37 1 4 870 34 1 4 7 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 4TTR6048B 4 1147 45 1 8 946 37 1 4 870 34 1 4 7 8 3...

Page 15: ...system controls include condenser fan and compressor contac tor High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor The Climatuff...

Page 16: ...Trane www trane com 05 13 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice...

Reviews: