background image

10

PUB. NO. 22-1802-03

Performance
Data

SW7

SW8

0.1

0.3

0.5

0.7

0.9

CFM

745

758

758

761

735

Temp. Rise

52

51

51

51

52

Watts

68

111

153

197

231

CFM

839

864

851

851

822

Temp. Rise

46

45

45

45

47

Watts

87

134

181

224

263

CFM

934

961

943

941

933

Temp. Rise

41

40

41

41

41

Watts

110

164

211

263

310

CFM

1064

1077

1085

1086

1077

Temp. Rise

56

55

55

55

55

Watts

152

205

262

325

379

CFM

1197

1226

1241

1230

1229

Temp. Rise

50

48

48

48

48

Watts

201

271

338

395

462

CFM

1345

1375

1376

1371

1320

Temp. Rise

44

43

43

43

45

Watts

272

348

418

480

517

High

OFF

Medium**

ON

ON

*UD2C080AFV42A

 

Furnace Heating Airflow (CFM) and Power (watts) vs. External Static Pressure With Filter

Airflow 

Setting

Dip Switch Setting

External Static Pressure

Low

High

Low

Medium**

ON

ON

Heat

in

g

Heating 

1st Stage

Heating 

2nd 

Stage

OFF

OFF

ON

ON

OFF

OFF

OFF

SW1

SW2

SW3

SW4

0.1

0.3

0.5

0.7

0.9

CFM

840

862

850

846

824

Watts

87

135

182

223

264

CFM

962

977

974

973

965

Watts

118

167

221

276

320

CFM

1076

1095

1104

1102

1096

Watts

153

212

271

331

390

CFM

1004

1018

1016

1019

1007

Watts

130

183

236

297

343

CFM

1143

1176

1187

1184

1180

Watts

180

267

311

368

436

CFM

1303

1334

1337

1334

1296

Watts

252

326

394

456

502

CFM

1167

1193

1208

1196

1193

Watts

190

255

321

378

443

CFM

1356

1378

1383

1358

1321

Watts

279

355

424

473

518

CFM

1521

1528

1537

1537

1344

Watts

379

545

534

606

556

CFM

1351

1376

1377

1364

1312

Watts

275

357

422

467

515

CFM

1537

1548

1561

1534

1347

Watts

392

468

552

606

538

CFM

1738

1755

1735

1568

1382

Watts

543

652

708

635

563

Notes:
1.  * First letter may be "A" or "T".
2.  ** Factory setting.
3.  Continuous Fan Setting:  Heating or cooling airflow is approximately 50% of selected cooling value.
4.  For variable speed low speed airflows are approximately 30% of listed values.
5.  LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
  HIGH 450 cfm/ton is for DRY CLIMATE setting.

OFF

OFF

ON

OFF

ON

ON

ON

ON

ON

*UD2C080AFV42A Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter

Dip Switch Setting

External Static Pressure

OFF

ON

OFF

ON

ON

ON

OFF

OFF

ON

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

4**

3.5

3

2.5

OFF

OFF

OFF

Low (350 

CFM/Ton)

Normal (400 

CFM/ton)

High (450 

CFM/ton)

OFF

OFF

ON

OFF

Airflow 

Setting

Normal (400 

CFM/ton)

High (450 

CFM/ton)

Low (350 

CFM/Ton)

Normal (400 

CFM/ton)

High (450 

CFM/ton)

Cooling

Unit 

Outdoor 

Low (350 

CFM/Ton)

Normal** 

(400 

High (450 

CFM/ton)

Low (350 

CFM/Ton)

Summary of Contents for TUD2B060AFV32A

Page 1: ...izontal 80 2 Stage Variable Speed Gas Fired Furnace with Whole House Air Cleaner PUB NO 22 1802 03 XV80i TUD2B060AFV32A TUD2B080AFV32A TUD2C080AFV42A TUD2B100AFV32A TUD2D120AFV52A 2009 Trane All Right...

Page 2: ...can be converted to L P gas INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors blowers gas valve flame control and includes self diagnos...

Page 3: ...pment Optional Equipment General Data TUD2B060AFV32A TUD2B080AFV32A TUD2C080AFV42A TUD2B100AFV42A TUD2D120AFV52A Performance Data Electric Data Field Wiring Diagrams Dimensions Contents 2 2 2 2 2 4 4...

Page 4: ...gauge aluminized steel heat exchanger Multi port In shot burners Complete front service access Alternate bottom left right return air Slide out blower assembly Hingedblowerdoor Perfect fit door catch...

Page 5: ...mostat Electronic Programmable 5 2 1 Stage Heating 1 Stage Cooling BAYSTAT340 Thermostat Heating Cooling Single Stage Mounts Vertically BAYSTAT305 Thermostat Electronic Programmable 2 Stage Heating 2...

Page 6: ...Variable SeeAirflow Table 1 2 Variable 115 1 60 Centrifugal Direct 2 1 100 2543 1727 115 1 60 0 70 0 40 Yes Whole House Air Cleaner 65 4Round Alum Steel Type 1 20 4 45 4 56 Redundant Two Stage Hot Su...

Page 7: ...Ignition Multi port In shot 6 115 1 60 15 3 20 1 2 H x W x D 41 3 4 x 26 1 2 x 30 1 2 40 x 24 1 2 x 28 1 2 193 181 UD2B100AFV32A Upflow Horizontal 65 000 52 000 100 000 80 000 40 70 Direct 10 x 7 1 V...

Page 8: ...137 198 259 316 361 CFM 831 883 915 935 941 Watts 122 182 238 292 345 CFM 1023 1052 1055 1061 1048 Watts 203 266 316 370 413 CFM 1156 1174 1188 1196 1085 Watts 280 351 415 482 442 CFM 1063 1094 1090...

Page 9: ...22 1111 1101 1083 Watts 269 317 361 405 442 CFM 1310 1295 1273 1246 1136 Watts 405 457 498 535 490 CFM 1458 1420 1369 1266 1154 Watts 569 599 606 561 506 CFM 1329 1310 1287 1253 1142 Watts 424 472 516...

Page 10: ...1334 1296 Watts 252 326 394 456 502 CFM 1167 1193 1208 1196 1193 Watts 190 255 321 378 443 CFM 1356 1378 1383 1358 1321 Watts 279 355 424 473 518 CFM 1521 1528 1537 1537 1344 Watts 379 545 534 606 55...

Page 11: ...atts 146 206 260 309 343 CFM 848 907 934 946 946 Watts 133 188 245 289 334 CFM 1018 1044 1055 1065 983 Watts 206 262 319 370 357 CFM 1139 1160 1184 1122 1020 Watts 274 344 411 417 386 CFM 1071 1089 11...

Page 12: ...563 640 605 CFM 1334 1376 1424 1411 1417 Watts 251 330 415 469 562 CFM 1582 1628 1659 1663 1465 Watts 387 491 595 672 595 CFM 1813 1836 1838 1707 1504 Watts 577 684 771 710 620 CFM 1704 1731 1733 1735...

Page 13: ...PUB NO 22 1802 03 WIRING DIAG WIRING DIAG WIRING DIAG WIRING DIAG WIRING DIAGRAMS FOR GAS FURNACES RAMS FOR GAS FURNACES RAMS FOR GAS FURNACES RAMS FOR GAS FURNACES RAMS FOR GAS FURNACES Electrical Da...

Page 14: ...22 1802 03 SCHEMA SCHEMA SCHEMA SCHEMA SCHEMATIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES TIC DIAGRAMS FOR GAS FURNACES Elect...

Page 15: ...s only for thermostats requiring connection to transformer common terminal 11 Optional humidistat is to be connected between R and BK Factory installed jumper R to BK on the circuit board must be cut...

Page 16: ...delays 9 Optional humidistat is to be connected between R and BK Factory installed jumper R to BK on the circuit board must be cut if optional humidistat is used The jumper must also be cut when apply...

Page 17: ...ER SEE NOTE 9 FIELD ADDED JUMPER W1 TO W2 2ND STAGE WILL FIRE 10 MINUTES AFTER 1ST B C B C TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STA...

Page 18: ...NOTE 9 W14 JUMPER SEE NOTE 9 From Dwg B342020 Rev 0 B C B C TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE 2 STAGE HEATING 1 ST...

Page 19: ...TRANSFORMER SEE NOTE 3 SEE NOTE 6 SEE NOTE 7 From Dwg B342018 Rev 0 B C B C TO 115 V 1 PH 60 HZ POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE 2 S...

Page 20: ...IN INCHES MODEL DIM A DIM B DIM C DIM D DIM E UD2B060AFV32A UD2B080AFV32A UD2B100AFV32A 17 1 2 9 5 8 16 1 4 16 16 UD2C080AFV42A 21 13 1 16 19 3 4 19 1 2 19 1 2 UD2D120AFV52A 24 1 2 15 5 16 23 1 4 23...

Page 21: ...NOTES...

Page 22: ...Since Trane has a policy of continuous product improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 www trane com...

Reviews: