SAFETY NOTICE 

Please read entire manual before installing your new furnace. Failure to follow these instructions may 

result in properly damage, bodily injury, or even death. 

Contact your local building and or fire officials about restrictions and inspection and permit 
requirements in your area.  
 
 
 
 
 
    
 
  
 

 

Summary of Contents for Anthraking 110K BTU

Page 1: ...liance for additional information SAFETY NOTICE Please read entire manual before installing your new furnace Failure to follow these instructions may result in properly damage bodily injury or even de...

Page 2: ...t has 20 x 20 standard 220k has 20 x 25 outlet 2 Jacket filler plate for flue outlet in Ship kit 3 Flue outlet 110k has 6 220K has 8 w gasket In ash pan 4 Blank cover for flue outlet w gasket In ash p...

Page 3: ...re Line Product Instructions will be provided with the Powervent for install At least 16 inches 400 mm in front and 8 inches 200 mm on either side of the fuel loading and ash removal doors Furnace is...

Page 4: ...alled to the furnace to be constructed of metal only The warm air supply duct system to be constructed of materials with a minimum temperature rating of 2500 F Install the thermostat in the room you w...

Page 5: ...an flues and chimney regularly DANGER Risk of Fire or Explosion Do not burn garbage gasoline drain oil or other flammable liquids CAUTION Hot Surfaces Keep children away Do not touch during operation...

Page 6: ...w room temp to get the FR to 0 3 Install ashpan 4 Install firestop ring at the end of the grate 5 Place starter bag on grate 6 Put desired amount of coal in the hopper 7 Make sure to cover the starter...

Page 7: ...ent in other areas General Carbon Monoxide Information Carbon monoxide is a colorless odorless and tasteless poison gas that can be fatal when inhaled CO inhibits the blood s capacity to carry oxygen...

Page 8: ...Combustion air is pre determined by blower size and should be correct from the factory if it is necessary combustion air can be reduced using a metal plate covering part of the intake side of the comb...

Page 9: ...or other combustible material within marked installation clearances Inspect and clean flues and chimney regularly DANGER Risk of Fire or Explosion Do not burn garbage gasoline drain oil or other flam...

Page 10: ...or ash removal doors open Do not store fuel or other combustible material within marked installation clearances Inspect and clean flues and chimney regularly DANGER Risk of Fire or Explosion Do not b...