BURN ANTHRACITE COAL ONLY
WARNING - Risk of Fire:- Do not operate with flue draft exceeding
-.07 in
. water column.
Operating at a number above -.07 can cause solid fuel devices to burn back into the hopper.
- Do on operate with fuel loading or ash removal doors open.
- Do not store fuel or other combustible material within marked installation clearances.
- Inspect and clean flues and chimney regularly.
DANGER - Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.
CAUTION
- Hot Surfaces: - Keep children away. - Do not touch during operation.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
Please save these instructions
Warning!!
Improper installation, adjustments, alterations, service, or maintenance of your Leisure Line Stove or Power Venter can cause
property damage, personal injury or loss of life.
Installation and service must be performed by a qualified installer or service agency.
Proper permits and inspections should always be obtained.
If applicable, please make sure you notify your insurance company before placing your stove into service.
Stove must be placed on a non-combustible surface.
UL ratings on all Leisure Line stoves and Power Venters are dependent on sufficient clearance as defined on the label on the rear
of your stove and in this manual.
All stoves must utilize a Barometric Draft Control such as the Field Controls Type RC Barometric Damper, the weights should be
adjusted to obtain a -.03” to -.05” water column negative pressure in the flue pipe at the stove outlet. Draft should be checked
using a draft meter or manometer. Over fire pressure can be checked by drilling a small ¼” hole in front of furnace usually below
top hinge on bottom door. It should be -.02 to -.03 water column no lower than -.01. Combustion air is pre-determined by blower
size and should be correct from the factory, if it is necessary combustion air can be reduced using a metal plate covering part of
the intake side of the combustion blower. Caution!! Do not increase blower size for increased firing for any reason
Utilize a magnetic thermometer to ensure that stove body temperature does not exceed 500* F.
If fans are installed in the storage area they should not create negative pressures in the room where the solid fuel-
burning appliance is located.
Outside combustion air may be necessary if:
1.
The solid-fuel-fired appliance does not draw steadily, smell, experiences smoke roll-out, burns poorly, or back-
drafts whether or not there is combustion present.
2.
Any of the above symptoms are alleviated by opening a window slightly on a calm day.
3.
The house is equipped with a well-sealed vapor barrier and tight fitting windows and/or has any powered
devices which exhaust house air.
4.
There is excessive condensation on windows in the winter.
5.
A ventilation system is installed in the house.
There are kits available from many suppliers run duct from outside air source as close to combustion blowers as
possible. Kits are available from most hearth shops and HVAC companies.
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground, well away from all combustible
materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container until all cinders have thoroughly cooled."
Inspect flue pipes, Joints and seals regularly to ensure flue gases are not drawing into and circulated
by the air circulation system .
Cleaning of the heat exchanger, flue pipe, and chimney / powervent system must be done at the end
of every season to prevent corrosion during the summer months caused by accumulated ash.