DM96SE / DC96SE

Single-Stage, Multi-Speed

ECM Gas Furnace

Up to 96% AFUE

Heating Input:  40,000 –120,000 BTU/h

■ 

Contents

Nomenclature ........................................ 2

Product Specifications

 ........................... 3

Dimensions

 ............................................ 5

Airflow Data

 ........................................... 7

 

DM96SE .............................................. 7

 

DC96SE ............................................. 10

Wiring Diagram .................................... 14

Accessories

 .......................................... 15

* Complete  warranty  details  available  from  your  local  dealer  or  at  www.daikincomfort.com.  To  receive  the  Lifetime  Heat  Exchanger  Limited 

Warranty (good for as long as you own your home), the 6-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, 
online registration must be completed within 60 days of installation. Additional requirements for annual maintenance are required for the Unit 
Replacement Limited Warranty.  Online registration and some of the additional requirements are not required in California or Québec.

■ 

Standard Features

■ 

Cabinet Features

• 

Heavy-duty stainless-steel tubular heat exchanger 

• 

Stainless-steel secondary heat exchanger

• 

Single-stage gas valve

• 

Durable Silicon Nitride igniter

• 

Multi-speed blower motor

• 

Self-diagnostic control board with constant 

 

memory fault code history output to a LED

• 

California Low NOx emissions-compliant models available 

• 

Can no longer be installed in California's South Coast Air 
Quality Management District (SCAQMD) on or after  

 

October 1, 2019. 

• 

AHRI Certified; ETL Listed

• 

Designed for multi-position installation: 

 

DM96SE: upflow, horizontal left or right

 

DC96SE: downflow, horizontal left or right

• 

Certified for direct vent (2-pipe) or non-direct vent (1-pipe) 

• 

Easy-to-install top venting with optional side venting

• 

Convenient left or right connection 

 

for gas and electrical service

• 

Cabinet air leakage (Q

Leak

) ≤ 2% 

• 

Heavy-gauge steel cabinet with durable finish

• 

Fully insulated heat exchanger and blower section

• 

Airtight solid bottom or side return with easy-cut tabs 

for effortless removal in bottom air-inlet applications

Summary of Contents for DC96SE 0403BN

Page 1: ...rd Features Cabinet Features Heavy duty stainless steel tubular heat exchanger Stainless steel secondary heat exchanger Single stage gas valve Durable Silicon Nitride igniter Multi speed blower motor Self diagnostic control board with constant memory fault code history output to a LED California Low NOx emissions compliant models available Can no longer be installed in California s South Coast Air...

Page 2: ... Downflow Horizontal A Initial Release B 1st Revision AFUE 97 97 98 AFUE 92 92 AFUE NOx 96 96 AFUE N Low Nox 40ng J Gas Valve Cabinet Width M Modulating A 14 V Two Stage S Single Stage B 17 C 21 Motor D 24 C Variable Speed ECM Communicating E Multi Speed ECM S Multi Speed PSC Maximum CFM 2 800 CFM MBTU h 3 1200 CFM 040 40 000 BTU h 100 100 000 BTU h 4 1600 CFM 060 60 000 BTU h 120 120 000 BTU h 5 ...

Page 3: ...ch 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire...

Page 4: ...ertified NO NO NO NO NO Natural Gas BTU h for altitudes 0 4500 above sea level reduce input rating by 4 for each 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada Minimum Circuit Ampacity 1 25 x Circ...

Page 5: ...20 19 20 5 9 19 34 19 B C 23 2 1 2 2 6 5 9 19 23 24 31 A 21 2 14 23 1 1 287 8 2 1 2 2 2 6 1 26 23 Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW Condensate Drain Trap Exterior Connection Right or Left Side PVC Vent Flue Pipe 2 PVC Alternate Vent Flue Location Right Side Drain Trap Exterior Holes High Volt...

Page 6: ...or Drain Trap Holes Low Voltage Electrical Outlet Air Discharge Air Discharge Folded Flanges B 18 Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0 0 3 NC 0 1 Horizontal 6 0 3 C 0 6 C If placed on combustible floor the floor MUST be wood ONLY NC For installation on non combustible floors only A combustible floor sub base must be used for installations...

Page 7: ...3 N A 800 N A 715 N A 627 561 496 ON OFF 1826 49 1783 50 1730 51 1685 53 1642 54 1596 1548 1504 ON ON 1465 N A 1402 N A 1360 N A 1306 N A 1250 N A 1197 1138 1073 OFF ON 1602 55 1556 57 1510 59 1460 N A 1411 N A 1372 1315 1261 DM96SE 1205D OFF OFF 1121 N A 1018 N A 933 N A 839 N A 762 N A 671 592 519 ON OFF 1969 54 1913 56 1862 57 1807 59 1756 61 1705 1647 1599 ON ON 1688 63 1626 N A 1564 N A 1500 ...

Page 8: ... ON 2215 2171 2137 2098 2060 2022 1986 1948 1908 1869 DM96SE 1005C OFF OFF 1012 940 863 800 715 627 561 496 437 374 ON OFF 1826 1783 1730 1685 1642 1596 1548 1504 1455 1406 OFF ON 1602 1556 1510 1460 1411 1372 1315 1261 1207 1156 ON ON 2225 2180 2141 2105 2070 2033 1996 1957 1923 1883 DM96SE 1205D OFF OFF 1121 1018 933 839 762 671 592 519 447 371 ON OFF 1969 1913 1862 1807 1756 1705 1647 1599 1544...

Page 9: ...10 935 861 785 721 631 553 483 423 350 ON OFF ON 1010 935 861 785 721 631 553 483 423 350 ON ON ON 1010 935 861 785 721 631 553 483 423 350 ON OFF OFF 1621 1570 1521 1467 1414 1378 1327 1274 1221 1167 ON ON OFF 1439 1400 1347 1291 1234 1182 1125 1065 1000 930 OFF ON OFF 1826 1775 1726 1684 1634 1588 1538 1492 1448 1398 OFF OFF ON 1843 1798 1753 1710 1666 1618 1574 1526 1481 1432 DM96SE 0805C OFF O...

Page 10: ...1205D OFF OFF 1296 N A 1190 N A 1076 N A 960 N A 839 N A 760 653 559 ON OFF 1917 56 1843 58 1759 61 1686 63 1600 67 1513 1420 1348 ON ON 1611 66 1521 70 1433 74 1347 N A 1246 N A 1145 1044 953 OFF ON 2011 N A 1936 N A 1858 N A 1779 N A 1692 N A 1610 1531 1442 at 0 5 ESP Notes CFM in chart is without filter s Filters do not ship with this furnace but must be provided by the installer If the furnace...

Page 11: ...5 OFF ON 2230 2176 2125 2086 2038 1999 1958 1917 1880 1829 DC96SE 1205D OFF OFF 1296 1190 1076 960 839 760 653 559 452 351 ON OFF 1917 1843 1759 1686 1600 1513 1420 1348 1258 1173 ON ON 2011 1936 1858 1779 1692 1610 1531 1442 1365 1266 OFF ON 2317 2257 2196 2122 2061 1990 1914 1762 1523 1232 at 0 5 ESP Notes CFM in chart is without filter s Filters do not ship with this furnace but must be provide...

Page 12: ...0 266 224 190 OFF ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF ON 760 686 613 542 459 376 310 266 224 190 ON ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF OFF 1390 1342 1292 1254 1201 1157 1112 1072 1022 985 ON ON OFF 1397 1361 1318 1266 1224 1181 1139 1095 1050 1003 OFF ON OFF 1581 1537 1492 1452 1413 1387 1347 1305 1267 1225 OFF OFF ON 1800 1758 1716 1678 1636 1601 1565 1529 1491 ...

Page 13: ...UT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Output BTU h x 1 000 Formulas BTU h Output CFM x 1 08 x Rise Rise BTU H Output CFM x 1 08 BTU Output Vs Temperature Rise Chart ...

Page 14: ...OWER PRESSURE SWITCH RD WH BURNER COMPARTMENT BLOWER COMPARTMENT NO YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT AUXILIARY LIMIT CONTROLS C FS LIMIT CONTROLS AUXILIARY IGNITER HOT SURFACE IND IGN BLWR CIRCULATOR BLWR ID FLAME SENSOR 115 VAC TRANSFORMER 40 VA 24 VAC GND CONTROL LIMIT PRIMARY AUTO RESET SINGLE CONTROL ON 40K BT...

Page 15: ...sion Kits Notes Indicates available for this model Indicates 9 001 to 11 000 altitude Indicates 7 001 to 9 000 altitude Indicates 7 001 to 11 000 altitude All installations above 7 000 require a pressure switch change For installation in Canada gas furnaces are certified only to 4 500 Model Description DM96SE 0403AN DM96SE 0603BN DM96SE 0803BN DM96SE 0804CN DM96SE 0805CNA DM96SE 1005CN DM96SE 1205...

Page 16: ...16 www daikincomfort com SS DM96SE Our continuing commitment to quality products may mean a change in specifications without notice 2021 Houston Texas Notes ...

Reviews: