TK 56460-19-OP-EN
25
Fan Selection
Evaporator fan speed is adjustable. Rotating the F
Fa
an
n selector knob clockwise
will increase fan speed; counterclockwise will decrease fan speed.
Figure 11.
Right Knob Adjusts Fan Speed
RCS1653
1
2
1.
Fan Selector
2.
LEDs
As fan speed increases LEDs will progressively turn on. As fan speed
decreases, LEDs will progressively turn off. The fan will continue to run at
the chosen speed.
•
AUTO fan speed is the default fan setting when Cool mode is selected.
This allows the Base Controller to make fan speed decisions for optimum
performance.
•
OFF may be selected when in Fan or Heat mode.
•
OFF is the default setting when Heat or Fan mode is selected.
Driver Selectable Settings
From the HMI the driver will have access to three additional selectable
features. To access these features the driver will use a sequence of “bumps”
on the On/Off (left) button. Pressing the On/Off button for ½ second is a
bump.
IIm
mp
po
orrtta
an
ntt:: The Selectable Settings Mode must be exited before the system
will resume normal operation.
•
A
Alla
arrm
m C
Clle
ea
arriin
ng
g:: Most active system alarms can be cleared from the
HMI.
–
TriPac Envidia system is on and the alarm icon is on.