Maintenance Inspection Schedule
Thermo King recommends all maintenance and service procedures be
performed by an authorized Thermo King dealer.
N
No
otte
e:: Thermo King reserves the right to deny warranty coverage on claims
due to lack of maintenance or neglect. Claims in question must be
supported by maintenance records.
Electrical
Pretrip
Semi-Annual
1,000
Hrs
Annual
2,000
Hrs
Check condition of or service the following:
•
•
Check tractor alternator operation and voltage per OEM specifications.
•
•
Verify indicator LEDs on the Smart Charger Modules (SCM) are
illuminated green.
•
•
Inspect and clean all tractor and TriPac Envidia battery terminals.
•
•
Inspect TriPac Envidia electrical connections for cleanliness and
tightness.
•
•
Inspect TriPac Envidia wire harness and battery cables for rubbing or
damage.
•
•
Check TriPac Envidia electric condenser and evaporator fans.