Page - 11
Pub. No. 22-5209-04
- Press and hold the Energy Savings keypad button to
gain Quick Access to the Energy Savings setup screen.
- Use the UP or DOWN arrow keys to change the
offset degrees setting.
NOTE:
Energy Savings offset degrees are selected separately for heating and cooling.
Press the Mode keypad button while viewing this screen to access the Cooling or Heat-
ing offset degrees setting, then use the UP or DOWN arrow key to select the desired
number of offset degrees.
- Press the Energy Savings keypad button again to return to normal display or just wait a
few seconds and the display will return on its own.
$
Page - 14
Pub. No. 22-5209-04
Filter Reminder
“
FILTER/OD”
will automatically flash to remind the homeowner that its time to
change the filter once the preset time has expired. Pressing the
“
FILTER/OD”
keypad
button automatically resets the internal clock timer. Once the timer has been reset, the
number of days remaining till the next filter change can easily be determined by simply
pressing the
“
FILTER/OD”
keypad button. Pressing and holding the
“
FILTER/OD”
keypad button provides quick access to the filter timer setup.
Energy Savings
The Energy Savings mode can provide energy savings by offsetting the indoor setpoint
to a cooler temperature setting for heating and a warmer temperature setting for cooling.
The Energy Savings mode is activated by pressing the Energy Savings key “$” on the
control keypad. Pressing the Energy Savings key “$” again deactivates the Energy Sav-
ings mode. Pressing and holding the Energy Savings key “$” provides quick access to
the offset degree setup for the current operating mode.
Default Factory Settings
The control is shipped with a set of factory default settings. The factory default settings
can be restored at any time using the control configuration menu. Please see Page 17 for
a complete listing of factory shipped default settings.
Features