background image

8

UNT-SVU001-EN

SLEEP Mode

This feature automatically adjusts the
temperature setting to provide
increased comfort and save energy
(The SLEEP display on LCD will
disappear after 1 hour).

COOLING Mode

- Press SLEEP button, one hour

after pressing, the air conditioner
will automatically raise the set
temperature by 1

0

C.

0

1

2

3

4

5

6

7

8

9

10

11

12

-2

O

C

-1

O

C

SET  POINT

START

NORMAL

SLEEP

HOUR

+1

O

C

+2

O

C

SLEEP  (COOLING  MODE)

By pressing SLEEP button, the unit will operate at SLEEP FUNCTION it will
automatically return to normal operation when the air-conditioner is switched
off and on again.

HEATING Mode

- Press SLEEP button, one hour

after pressing, the air conditioner
will automatically reduce the set
temperature by 1

O

C.

(The SLEEP display on LCD will
disappear after 1 hour).

SWEEP Operation

The 

SWEEP

 function will operate in

either 

cooling

 or 

heating

 mode to

rapidly distribute conditioned air into
the room.
- The supply air grille will be fully

closed when the unit is off.

- When the unit is turned on, the

grille will open to the fully open
position.

- After the unit has been turned on,

pressing the SWEEP button will
sweep the supply air grille back
and forth to rapidly distribute and
cool (or heat) the room.

- If the unit is in SWEEP mode,

pressing the sweep button will
return the grille to the fully open
position.

- Press the POWER button while the

unit is in operation, will turn off the
unit and the supply air grille will
automatically close.

LOUVER Operation

The direction of the airflow can be
controlled
- Press LOUVER button to adjust the

angle of the blade to control the
direction of the air flow.

Note:

 The sweep and louver

operations are optional functions of
MCX 512 - MCX 524. These opera-
tions are not available in the models
that have cooling capacity more than
24,000 Btu.

0

1

2

3

4

5

6

7

8

9

10

11

12

START

NORMAL

SLEEP

HOUR

SLEEP  (HEATING  MODE)

By pressing SLEEP button, the unit will operate at SLEEP FUNCTION it will
automatically return to normal operation when the air-conditioner is switched
off and on again.

-2

O

C

-1

O

C

SET  POINT

+1

O

C

+2

O

C

Summary of Contents for CFEA 04 CEM1

Page 1: ...CFEA 20 COM1 60 Hz Models Cooling Only CFEA 04 COM2 CFEA 06 COM2 CFEA 08 COM2 CFEA 10 COM2 CFEA 12 COM2 CFEA 14 COM2 CFEA 16 COM2 CFEA 20 COM2 Cooling Heating CFEA 04 CEM1 CFEA 06 CFM1 CFEA 08 CBM1 CF...

Page 2: ...ny damage of the unit on the delivery note and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery Notify the dealer at the same time The unit should be to...

Page 3: ...UNT SVU001 EN 3 Contents General Information 2 Control Operation 4 Wireless Remote Control 5 Wired Control 9 System Operation 12 Maintenance 13 Troubleshooting 14 Notes 15...

Page 4: ...ER Lamp This lamp lights when the system is being controlled by the timer One Touch Control Switch A This button is used for adjusting operation without remote control unit This press switch is for se...

Page 5: ...peration 6 Temperature Setting Button TEMP Press this button to increase the set temperature TEMP Press this button to decrease the set temperature 7 FAN Button Press this button to select fan speed 8...

Page 6: ...e indicated 8 System Mode Displays the current operation mode In cooling only FAN COOL or DRY In cooling and heating system FAN COOL DRY or HEAT FAN COOL DRY HEAT START STOP HIGH MED LOW AUTO 1 2 3 4...

Page 7: ...o cancel the STOP timer press STOP button again Setting START Timer You can set the START timer to start the unit automatically at any desired time up to 24 hour ahead Press POWER button to turn on th...

Page 8: ...rille will be fully closed when the unit is off When the unit is turned on the grille will open to the fully open position After the unit has been turned on pressing the SWEEP button will sweep the su...

Page 9: ...System MODE Selector Switch Temperature Setting Wheel Set Point Indicator COOL FAN Cooling Only Model Control and their functions To operate the unit follow these steps Set the temperature on the sett...

Page 10: ...n switch Adjust the set point temperature on the temperature setting wheel to the desired setting The temperature set point may be changed while the unit is in operation Select the FAN SPEED to high m...

Page 11: ...just the air flow direction properly otherwise it may cause discomfort and make the room temperature uneven Up Down Right Left Adjust Air Flow Direction with sweep option The sweep motor will sweep th...

Page 12: ...y hand The insulation of the power cord is exposed at any point The fuse is blown or circuit breaker trips frequently The functions of the switches are inaccurate System Operation Operating Air Condit...

Page 13: ...each air filter frame from the return air grille 1 2 How to clean the air filter Wash away dust from the air filter with clean water or vacuum it with an electric vacuum cleaner Pull Pull Pull Upward...

Page 14: ...If opened close it Check whether there are sources of heat in the room cooling is less effective Check whether the return air inlet or the supply air outlet on the indoor unit and outdoor unit are bl...

Page 15: ...UNT SVU001 EN 15 Notes...

Page 16: ...to change design and specifications without notice Trane Thailand 7 th Floor Ploenchit Center Building 2 Sukhumvit Road Klongtoey Bangkok 10110 http www trane com An American Standard Company Literat...

Reviews: