Installer’s Guide

Figure 12. 2/4WC** & 4DC**  Single Phase 230 Volt Heat Pump Models

7b.  2/4WC** & 4DC** Single Phase 230 Volt Heat
Pump Models. See Figure 12.

Disconnect and remove the black lead from the De-
frost Board relay to the "L2" terminal of the contactor
(the black wire is attached to the “COM” terminal of
the relay). Firmly hold relay when removing wire.
Connect one of the black leads from the (SSR) on the
Control Module to the position on the unit contactor
"L2" (where the previous wire was removed). Connect
the other black lead on the (SSR) on the Contoller
Module to the "COM" terminal on the Defrost Board.

Connect Low voltage wires (BYO):

1.

Connect the 3-pin BYO low voltage wire harness
(supplied in kit) to J5 on the Control Module (3-
pin male connector).  See Figure 11. 

Note:

 to ease

the insertion of the connector housing on to the J5
header, place the connector on the tips of the three
header pins.  Angle the connector upward toward
the header latch while pushing connector over the
header pins.

2.

Connect the 

yellow

 lead wire of the harness to a

¼  ” male tab on the right hand side of the main
contactor (low voltage contactor coil terminal). See
Figure 12.

3.

Connect the 

blue

 lead wire of the harness to the

wire nut junction of the blue wire (use new wire
nuts in kit).

4.

Connect the 

orange

 wire to the wire nut junction

of the orange wire (use new wire nuts from kit).

5.

Connect the Liquid Line Sensor to J2 on the
Control Module. See Figure 11.

6.

Connect the Outdoor Temperature Sensor (Ambi-
ent Sensor) to J3 on the Control Module.

7.

Reinstall louvers and panels. Continue with step 

8.

System Setup, page 14

.

1

1

2

3

4

ON

ON

OFF

OFF

S2

S2

TEST

TEST

S1

S1

AMBIENT

AMBIENT

LIQUID

LIQUID

B

Y

O

ALERT

ALERT

Lite

Lite

Port

Port

RED

RED
LED

LED

GREEN

GREEN
LED

LED

S2-1,2,3,4

S2-1,2,3,4
DIP SWITCHES

DIP SWITCHES

S1

S1
TEST

TEST
SWITCH

SWITCH

AMBIENT

AMBIENT

SENSOR

SENSOR
(OUTDOOR

(OUTDOOR
TEMP SENSOR)

TEMP SENSOR)

LIQUID

LIQUID
LINE

LINE

SENSOR

SENSOR

B,Y,O

B,Y,O

J5

J5

J2

J2

J3

J3

Figure 11. Control Module Switches, Connectors, and LEDs

IMPORTANT

 — Retain this wiring diagram; please return this document to service information pack upon completion of work.

Summary of Contents for BAYLOAM105AA

Page 1: ...ontrol Module is to be mounted to the universal bracket included in the kit or the Compressor Startkit bracket depending upon your unit s configuration Continue with the following section that applies...

Page 2: ...LOAM Kit Components Note Unit vents not shown Universal Bracket Liquid Sensor Clamp Bushing Wire Nuts 5 Cable Ties 5 Liquid Sensor Assembly Thermal Compound Outdoor Air Sensor Retainer Dart Informatio...

Page 3: ...ressor Start Kit bracket using the two 2 machine screws See Figure 3 3 Continue with step 4 Mounting the Liquid Line Sensor page 7 Figure 3 230 Volt 2 4WC with Compressor Start Kit 460 Volt 2 4WC 3060...

Page 4: ...s 230 460 Volt Three Phase 2 4WC units except for 2 4WC 3060A4 460 Volt 4WCZ6 units Mount Universal Bracket to back wall of Control Box with two 2 Sheetmetal Screws horizontally Control Box Mount Univ...

Page 5: ...5 230 Volt 2 4YC and 4DC units with Compressor Start Kit 460 volt 2 4YC 3060A4 460 volt 4YCZ6 units 3 Mount the Control module to the Start Kit bracket with the two 2 machine metal screws you removed...

Page 6: ...to the bottom of the control box with two 2 sheetmetal screws One is inserted horizontally from inside the control box into the universal bracket and one is inserted vertically See Figure 6 Figure 6 2...

Page 7: ...utside of the outdoor coil See Figure 9 page 8 1 On the outdoor fan grill remove eight 8 plastic screw caps covering the fan screws Then remove the eight 8 screws that secure the outdoor fan grill to...

Page 8: ...e Sensor OUTDOOR TEMPERATURE SENSOR DART OUTDOOR TEMPERATURE SENSOR WIRES LIQUID LINE SENSOR WIRES LOUVERED PANEL REMOVE 3 SCREWS LIFT PANEL UP TO UNHOOK FROM SLOT REMOVE 8 FAN GRILL SCREWS TO ROUTE O...

Page 9: ...lead with a wire nut supplied Connect the other black wire from the solid state relay SSR to the contactor terminal L2 from where the fan motor lead was disconnected Connect Low voltage wires BYO 1 Co...

Page 10: ...over the header pins 2 Connect the yellow lead wire of the harness to a male tab on the right hand side of the main contactor low voltage contactor coil terminal See Figure 12 3 Connect the blue lead...

Page 11: ...he insertion of the connector housing on to the J5 header place the connector on the tips of the three header pins Angle the connector upward to ward the header latch while pushing connector over the...

Page 12: ...ector over the header pins 2 Connect the yellow lead wire of the harness to a male tab on the right hand side of the main contactor low voltage contactor coil terminal See Figure 15 3 Connect the blue...

Page 13: ...f the three header pins Angle the connector upward toward the header latch while pushing connector over the header pins 2 Connect the yellow lead wire of the harness to a male tab on the right hand si...

Page 14: ...has not yet acquired an approach temperature S2 dip switch 1 2 and 3 settings are used for determining the liquid temperature set point the same as in Manual Mode If the Control Module has acquired an...

Page 15: ...c e S g n i h s a l F f f O d n o c e S t l u a F r o s n e S t n e i b m A y l s u o u n i t n o c N O d r a o b t l u a F M O R P E E C 2 I e l b a r i a p e r d l e i f t o N e r u l i a f working...

Page 16: ...ler s Guide Trane 6200 Troup Highway Tyler TX 75707 9010 The manufacturer has a policy of continuous product and product data improvement It reserves the right to change design and specification witho...

Reviews: