General Data
CG-SVX06D-E4
10
Table 5 - Condenserless units: CCUN standard - R407C
CCUN
CCUN
CCUN
CCUN
212
213
214
215
Eurovent Performances (1)
Net Cooling Capacity
(kW)
385.6
417.3
450.4
486.9
Total Power input in cooling
(kW)
99.0
108.5
120.5
131.1
Evaporator water pressure drop
(kPa)
38
44
46
45
Evaporator head pressure available (4)
(kPa)
242
227
211
197
Main Power supply
400/3/50
Sound Power Level (4)
(dBA)
87
88
88
90
Sound Power Level w/ sound attenuation jacket (4)
(dBA)
84
85
85
87
Units Amps
Nominal (3)
(A)
280
306
339
369
Start-up Amps
Standard unit
(A)
532
557
590
624
With soft starter option
(A)
408
434
467
499
Short circuit unit capacity
(kA)
15
15
15
15
Max supply cable size
(mm
2
)
185
185
240
240
Min supply cable size
(mm
2
)
240
240
240
240
Compressor
Number
5
6
6
6
Type
Scroll
Model
(25T+30T)
(25T)
(25T+30T)
(30T)
Speeds number
1
Motors Number
1
Rated Amps (compA/CompB) (3)
(A)
52/62.5
52/52
52/62.5
62.5/62.5
Locked rotor Amps (compA/CompB)
(A)
272/310
272/272
272/310
310/310
Motor RPM
(rpm)
2900
2900
2900
2900
Power factor (compA/CompB)
0.87/0.87
0.87/0.87
0.87/0.87
0.87/0.87
Sump Heater (compA/CompB)
(W)
150
150
150
150
Evaporator
Number
1
Type
Brazed plate
Model
AC350-190DQ
AC350-190DQ
AC350-210DQ
AC350-230DQ
Water volume (total)
(l)
38
38
42
46
Antifreeze Heater
(W)
no
no
no
no
Evaporator Water Connections
Grooved pipe connections
Diameter
4"
Max. water-side operating pressure,
without hydraulic module
(kPa)
1000
1000
1000
1000
with hydraulic module
(kPa)
400
400
400
400
Remote condenser connections
Discharge line diameter circuit 1 & 2
2"1/8
2"1/8
2"1/8
2"1/8
Liquid line diameter circuit 1 & 2
1"3/8
1"3/8
1"3/8
1"3/8
Dimensions without Hydraulic Module
Height
(mm)
1950
1950
1950
1950
Length
(mm)
2808
2808
2808
2808
Width
(mm)
878
878
878
878
Dimensions with Hydraulic Module
Height
(mm)
1950
1950
1950
1950
Length
(mm)
3498
3498
3498
3498
Width
(mm)
878
878
878
878
Operating Weight
Base Unit w/o Hyd Kit
(kg)
1879
2070
2120
2180
Base Unit with Hyd Kit
(kg)
1880
2071
2122
2182
Evap Hyd Kit
(kg)
490
490
490
490
Shipping Weight
Base Unit w/o Hyd Kit
(kg)
1832
2023
2070
2130
Base Unit with Hyd Kit
(kg)
1842
2033
2080
2136
Evap Hyd Kit
(kg)
432
432
432
432
System Data
Refrigerant circuit
2
Capacity steps
4
4
4
4
Minimum capacity
%
22
33
30
33
Refrigerant Charge (2)
Circuit A & B
(kg)
Holding charge
Oil Charge (2)
Circuit A & B
(l)
20.4 / 12.6
20.4 / 20.4
18.9 / 20.4
18.9 / 18.9
(1) Conditions (Evap 12°C/7°C - Saturated discharge 45°C - 5°C subcooling)
(3) Max rated conditions.
(2) per circuit
(4) Dual Pump Option