background image

8

UNT-SVN009-EN

Remote Control Installtion

ECONO

ECONO

ON

FAN

COOL

DRY

HEAT
AUTO

OFF

POWERCOOL

SW

Z

Z

MODE

LOUVER

SWEEP

FRONT

BLADE

LIGHT

OFF

ON

POWER

COOL

ECONO

SLEEP

SEND

Locate and attach the
wireless remote control
and wired control as
follows:

1. Do not place the control and

the remote control near heat
sources or expose to the direct
rays of the sun.

2. Do not expose the control to the

indoor unit’s supply air stream.

3. Do not place in a confined

space.

4. Attach the remote control holder

as shown in Figure 13, 14.

Dimension

Wireless Remote Control

Wired Remote Control

Mounting Bracket

Figure 13

Figure 14

TEMP

MENU

MODE

FA

N

ON

ON

OFF

OFF

ECONO

SW

SLEEP ECONO 

TURBO

TURBO

AU

TO

14.5

4.0 X 2

SLOT

14.5

45.0

90.0

45.0

90.0

61.0

UNT-SVN009-EN.p65

9/9/09, 9:57 AM

8

Summary of Contents for AQUA NEW STYLUS CFEB 04 C0M1

Page 1: ...Series 50 60 Hz 50 Hz Models Cooling Only CFEB 04 C0M1 CFEB 06 C0M1 CFEB 08 C0M1 CFEB 10 C0M1 CFEB 12 C0M1 CFEB 14 C0M1 CFEB 16 C0M1 CFEB 20 C0M1 60 Hz Models Cooling Only CFEB 04 C0M2 CFEB 06 C0M2 CF...

Page 2: ...fy the dealer at the same time The unit should be totally inspected within 7 days of delivery If any concealed damage is discovered send a registered letter of protest to the carrier within 7 days of...

Page 3: ...ation 5 Connection of Water Piping 6 Position of Piping Hole 6 Condensate Drain Piping 7 Electrical Installation 7 Remote Control Installation 8 Electronic Room Thermostat 9 Installation Typical Wirin...

Page 4: ...be kept as short as possible Figure 1 6 Do not install unit in direct sunlight or near other heat sources as this may affect performance Do not allow outside air to directly enter unit or condensate...

Page 5: ...nward 5 Pull air filters upward Figure 6 0 83 17 5 0 83 17 5 8 5 215 B A 6 Unscrew at the return grille Figure 7 7 Unscrew at the grille bottom hinges pull out the screw and unscrew at the side panel...

Page 6: ...piping connections connect the female connections to the male adapter of the water piping connections at the inlet and outlet of the coil Then screw in and fasten the connections with an adjustable w...

Page 7: ...iring Important Safeguards Check the unit nameplate for electrical rating Be sure wiring is done according to local codes and wiring diagram Connect electrical ground to all units Wiring should not to...

Page 8: ...he remote control near heat sources or expose to the direct rays of the sun 2 Do not expose the control to the indoor unit s supply air stream 3 Do not place in a confined space 4 Attach the remote co...

Page 9: ...ocated at or near the water drop or water mist Be careful not to leave any copper wire or piece of metal inside the control set Precaution This room thermostat is an electronic control device which re...

Page 10: ...10 UNT SVN009 EN Typical Wiring Diagram WIRING DIAGRAM UNT SVN009 EN p65 9 9 09 9 57 AM 10...

Page 11: ...11 UNT SVN009 EN Typical Wiring Diagram CFEB CHILLED WATER FANCOIL UNIT WITH WIRELESS CONTROL COOLING ONLY UNT SVN009 EN p65 9 9 09 9 57 AM 11...

Page 12: ...12 UNT SVN009 EN CFEB CHILLED WATER FANCOIL UNIT WITH WIRED CONTROL COOLING ONLY Typical Wiring Diagram UNT SVN009 EN p65 9 9 09 9 57 AM 12...

Page 13: ...0 0 59 627 1 24 71 A RUBBER ISOLATOR QTY C 254 3 10 02 359 1 14 15 74 2 2 93 234 3 9 23 RETURN AIR OUTLET CONNECTION INLET CONNECTION 610 7 24 06 123 1 215 0 143 6 DIMENSIONAL DATA 6 4 4 REV A 035 10...

Page 14: ...6 RETURN AIR 234 3 9 23 74 2 2 93 OUTLET CONNECTION INLET CONNECTION 400 0 15 76 42 0 1 65 131 5 5 18 D 375 0 14 78 140 0 5 52 DIMENSIONAL DATA 8 8 REV B 035 1047 Sept 08 09 ECN NO 09114 09221 OUTLET...

Page 15: ...15 UNT SVN009 EN Notes UNT SVN009 EN p65 9 9 09 9 57 AM 15...

Page 16: ...Literature Order Number UNT SVN009 EN Date Sep 2009 Supersedes Apr 2008 Stocking Location Bangkok Thailand UNT SVN009 EN p65 9 9 09 9 57 AM 16...

Reviews: