3
3
Test Mode
Installer’s Guide
Test Mode
Test Mode
Settings
Description
Blower (Non-VS)
Blower On
Energize "G" circuit
Blower (VS)
50%, 100%
Energize "G" and "BK" circuit
Cooling
Single Stage, 1st Stage, 2nd Stage Energize selected "Y", "Y1" or "Y2", "O" and "G" circuit (BK also for
VS indoor unit)
Comp Heating
Single Stage, 1st Stage, 2nd Stage Energize selected "Y", "Y1" or "Y2" and "G" circuit ("BK" also for VS
indoor unit)
Indoor Heating
Single Stage, 1st Stage, 2nd Stage Energize selected "W", "W1" or "W2" ("G" circuit also for electric heat)
Aux Relay
Relay On
Close normally open dry contacts
Once testing is complete, press the Done button to exit and return to Menu.
Test Mode allows the servicer to test system operation without waiting for the system to stage up/down. Also all
minimum on and off times are disabled during test mode. Once a specific test has started, the test will last for 30
minutes unless the servicer ends the test by pressing the Done button. A countdown timer will be displayed during test
mode indicating how much time is left in the test. To access Test Mode press the Menu button, then press Next until
Service is displayed. Now press Select and hold for 5 seconds until “Installer Settings” is displayed. Press Next until
Test Mode is displayed. Now press Select again to enter Test Mode.
Restore Defaults
Setting
Range
Description
Restore Default
Yes, [No]
Select "Yes" to restore all the
User
and
Installer
settings to the
factory defaults. If "Yes" is selected "Restoring" will be displayed.
"Done" will be displayed once all settings have been restored.
Note: To reset all
User
,
Installer
and
Z-Wave
settings, press and hold the "Yes" button for 5 seconds. Release when "Factory Defaults" is
displayed. "Done" will be displayed once all settings have been restored and the control will automatically return to the home screen..
Restore Defaults
Restore Defaults is used to restore the control to factory default settings. To access “Restore Defaults” press the
Menu button, then press Next until “Service” is displayed. Now press Select and hold for 5 seconds until “Installer
Settings” is displayed. Press Next until “Restore Default” is displayed. Now press Select again to enter “Restore
Default”. The default setting will be shown in brackets. After each selection press Done to save changes.