background image

©2021 Trane

BAS-SVP046A-EN

Introduction

Read this manual thoroughly before operating or servicing this unit.

Warnings, Cautions, and Notices

Safety advisories appear throughout this manual as required. Your personal safety and the
proper operation of this machine depend upon the strict observance of these precautions.

The three types of advisories are defined as follows:

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, could result in
minor or moderate injury. It could also be used to alert against unsafe practices.

NOTICE

Indicates a situation that could result in equipment or property-damage only
accidents.

Important Environmental Concerns

Scientific research has shown that certain man-made chemicals can affect the earth’s naturally
occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the
identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine,
Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon
(HCFCs). Not all refrigerants containing these compounds have the same potential impact to the
environment. Trane advocates the responsible handling of all refrigerants-including industry
replacements for CFCs and HCFCs such as saturated or unsaturated HFCs and HCFCs.

Important Responsible Refrigerant Practices

Trane believes that responsible refrigerant practices are important to the environment, our
customers, and the air conditioning industry. All technicians who handle refrigerants must be
certified according to local rules. For the USA, the Federal Clean Air Act (Section 608) sets forth
the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and
the equipment that is used in these service procedures. In addition, some states or municipalities
may have additional requirements that must also be adhered to for responsible management of
refrigerants. Know the applicable laws and follow them.

W

WA

AR

RN

NIIN

NG

G

P

Prro

op

pe

err F

Fiie

elld

d W

Wiirriin

ng

g a

an

nd

d G

Grro

ou

un

nd

diin

ng

g R

Re

eq

qu

uiirre

ed

d!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w cco

od

de

e cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr sse

erriio

ou

uss iin

njju

urry

y..

A

Allll ffiie

elld

d w

wiirriin

ng

g M

MU

US

ST

T b

be

e p

pe

errffo

orrm

me

ed

d b

by

y q

qu

ua

alliiffiie

ed

d p

pe

errsso

on

nn

ne

ell.. IIm

mp

prro

op

pe

errlly

y iin

nsstta

alllle

ed

d a

an

nd

d

g

grro

ou

un

nd

de

ed

d ffiie

elld

d w

wiirriin

ng

g p

po

osse

ess F

FIIR

RE

E a

an

nd

d E

EL

LE

EC

CT

TR

RO

OC

CU

UT

TIIO

ON

N h

ha

azza

arrd

dss.. T

To

o a

av

vo

oiid

d tth

he

esse

e h

ha

azza

arrd

dss,,

y

yo

ou

u M

MU

US

ST

T ffo

ollllo

ow

w rre

eq

qu

uiirre

em

me

en

nttss ffo

orr ffiie

elld

d w

wiirriin

ng

g iin

nsstta

alllla

attiio

on

n a

an

nd

d g

grro

ou

un

nd

diin

ng

g a

ass d

de

essccrriib

be

ed

d iin

n

N

NE

EC

C a

an

nd

d y

yo

ou

urr llo

occa

all//sstta

atte

e//n

na

attiio

on

na

all e

elle

eccttrriicca

all cco

od

de

ess..

Summary of Contents for Symbio 800

Page 1: ...ic knowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in t...

Page 2: ...actices are important to the environment our customers and the air conditioning industry All technicians who handle refrigerants must be certified according to local rules For the USA the Federal Clea...

Page 3: ...st tr ru uc ct ti io on ns s I If f t th he er re e i is s a a r ri is sk k o of f e en ne er rg gi iz ze ed d e el le ec ct tr ri ic ca al l c co on nt ta ac ct t a ar rc c o or r f fl la as sh h t...

Page 4: ...Configuration 6 Service Tool for Symbio 800 Configuration 6 Connecting to the Symbio 800 Web Interface 7 Protocol Configuration 8 LonTalk Protocol Settings 8 Profile Definition and Network Variables...

Page 5: ...MS TP BACnet IP BACnet Zigbee Air Fi BACnet IP Ethernet Wi Fi Modbus RTU Modbus TCP LonTalk For information pertaining to the integration of the Symbio 700800 controller using either Modbus or LonTal...

Page 6: ...or BACnet MS TP communications at 76 800 bps with a rotary address setting of 000 Figure 1 Symbio 800 rotary address and service tool port Service Tool for Symbio 800 Configuration The service tool us...

Page 7: ...Symbio 800 page displays click L Lo og g I In n Figure 2 Symbio 800 log in screen N No ot te e The Symbio 800 web interface can only be viewed using the USB connection Ethernet port 1 and Ethernet po...

Page 8: ...mmunications 4 Click the P Pr ro ot to oc co ol l C Co on nf fi ig gu ur ra at ti io on n tab Figure 4 Protocol Configuration 5 View the existing Protocol Configuration settings N No ot te e There are...

Page 9: ...message to the LonTalk network A service pin will broadcast the Neuron ID to the LonTalk network so a LonTalk network management tool can find a device and set its Domain Subnet Node address LonTalk c...

Page 10: ...e Location 6 nciNoiseRdcnReq SNVT_switch Default for Noise Reduction Auto On Request Noise Reduction request 7 nciRefrigerant UCPT_refrig_type Chiller Refrigerant Type Refrigerant Type 8 nciCapacityLi...

Page 11: ...pacity SNVT_lev_percent Actual Running Capacity of Unit 0 03 Chiller Power 40 nvoCapacityLim SNVT_lev_percent Current Capacity Limit Setting of Chiller 0 01 Active Demand Limit Setpoint 41 nvoLvgCHWTe...

Page 12: ...30 0 kPa Condenser Refrigerant Pressure Ckt1 69 nvoCondRfgtPrsC2 SNVT_press_f Condenser Refrigerant Pressure Circuit 2 30 0 kPa Condenser Refrigerant Pressure Ckt2 70 nvo CondRfgtTmpC1 SNVT_temp_p Con...

Page 13: ...fault Values 12 nciDevMajVer SCPTdevMajVer The major version number for the device Software Major Version 13 nciDevMinVer SCPTdevMinVer The minor version number for the device Software Minor Version 1...

Page 14: ...03 Cooling only HVAC_FREE_COOL 0A Cooling with compressor not running HVAC_ICE 0B Ice making mode u8 01234567 in_alarm bit 0 MSB in alarm mode Diagnostic Present run_enabled bit 1 run enabled Run Enab...

Page 15: ...Air Flow Ckt1 73 nvoAirFlowPctC2 SNVT_lev_percent Air Flow Percent Circuit 2 5 00 Air Flow Ckt2 76 nvoHiSideOilPrsA SNVT_press_f High Side Oil Pressure Compressor A 20 0 kPa Oil Pressure Compressor 1...

Page 16: ...nvoStartsRunTmD UNVT_starts_runtime Starts and Run Time Compressor D defined at element SNVT_count_f Starts 1 Starts Compressor 2A SNVT_time_f Run Time 360 sec Running Time Compressor 2A 118 nvoUnitP...

Page 17: ...ed as full auto the BMS value is used instead of the local or default values The point designator with the arbitrator suffix includes the full priority array allowing the user to see the value associa...

Page 18: ...hecking software maintenance plan U4 Reformatting main filesystem clearing database U5 Beginning update U12 Searching for scfw files on USB drive s U51 Updating main firmware U54 Updating FPGA image U...

Page 19: ...ry devices only and should not have any other devices added this link Figure 10 P3 machine bus global bus internal communication bus N No ot te e The P3 link is intended for factory devices only and s...

Page 20: ...e XM70 Figure 12 4 USB connectors The controller automatically detects devices on any of the ports not port specific The controller ships with all ports enabled but they can be disabled via the Web in...

Page 21: ...t Trane approved such as cellular phones Figure 13 Ethernet port 2 Touch Screen Display N No ot te e Ethernet Port 2 is for use with the Touch Screen display only Communication to other devices is not...

Page 22: ...22 BAS SVP046A EN N No ot te es s...

Page 23: ...BAS SVP046A EN 23 N No ot te es s...

Page 24: ...plications For more information please visit trane com or tranetechnologies com Trane has a policy of continuous product and product data improvements and reserves the right to change design and speci...

Reviews: