14 TECHNICAL DATA
Ex Protection:
Ex II 2 G Ex db op is IIB+H
2
T5 Gb
Area of Use:
Hazardous areas Zone 1 or 2, EPL Gb and safe area
Materials:
Powder coated seawater resistant aluminum, tempered glass.
Input Voltage:
16-32V DC
Current consumption:
Main Light: Max. 6.15A @16V
Repeater Light: Max. 0.41A @16V
Power, Main Light:
Peak: Max. 98W
Average: Max. 30W
Standby: Max. 1.8W
Power, Repeater Light :
Peak: Max. 7.3W
Average: Max. 2.6W
Standby: Max. 1.8W
Digital Inputs :
‘0’: -3V to +5V
‘1’: +11V to +32V
Typical current consumption: 2mA @ 24VDC
Digital output:
Voltage: U
in
– 1.2V @2.4mA
Max. output current: 25mA
Light intensity, Main Light:
Min. 700cd 2°-10° elevation
Min. 176cd 0°-90° elevation
Light intensity,
Repeater Light and Main Light in Dim Mode:
Min. 16cd 0°-90° elevation
Max. 60cd 0°-90° elevation
Color:
Red. According to ICAO Annex 14. NVG compatible IR LED`s.
Flash rate:
Standard Mode: 120 flashes pr. min.
«Dim» Mode: 60 flashes pr. min.
Flying lead cable:
7 x 1.5mm
2
with screen. Flame retardant, halogen-free and mud resistant.
Standard length: 3 meters. Ø17mm ±0.8.
Ingress Protection:
IP 66/67
Operating Temperature:
-40°C to +55°C
Overall dimensions 9980000/ 9980005:
200x263x245mm (excluding cable) (L x W x H)
Overall dimensions 9980006:
200x263x138mm (excluding cable) (L x W x H)
Weight 9980000/ 9980005:
11.5 kg.
Weight 9980006:
TBA
Compliance standards:
CAA UK CAP437:2013, NORMAM-27/DPC:2015, 2009 MODU Code:2010,
IEC 60079-0 ed. 7, IEC 60079-1 ed. 7, IEC 60079-28 ed. 2,
EN 60079-0:2012/A11:2013, EN 60079-1:2014,
EN 60079-28:2015, EN 61000-6-2:2005, EN 61000-6-4:2007,
EN 61547:2009, EN 50581:2012, IEC 60533:2015