background image

OmniCounter

OmniCounter

 

 

Wireless 

Wireless 

Infrared People Counter

Infrared People Counter

 

 

 

 

Model: OmniCounter

Model: OmniCounter

 

 

 

 

Traf-Sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 

Page 4 of 9 

Ph: 888-815-6568 | Fax: 928-222-7279 | 

www.trafsys.com

 

Mounting Bracket   

You should decide what mode you are going to use your counters in before hanging 
the mounting brackets. You will want to mount each mounting bracket (shown below) 
with snap lock facing up for front firing mode to allow for proper orientation and 
sensor operation. For side 
firing the bracket will have 
one snap lock facing up and 
the other facing down to 
allow for proper orientation 
and sensor operation. For 
dual (directional) mode the 
brackets need to be mounted 
horizontally. Both of the 
brackets will have the snap 
lock facing the inside of the 
door to allow for proper 
orientation and sensor operation. 
 

 

After mounting the brackets, your Omni Counter sensors simply slide onto the Slide 
lock and then snap securely onto the Snap lock. The following guide will help 
illustrate the process. 

 

           Figure 1                              Figure 2                                   Figure 3                    
 

               Figure 1: Grasp the sensor firmly and line it up with the Slide lock. 

               Figure 2: Slide the sensor onto the Slide lock. 

               Figure 3: Begin to push the sensor towards the Snap lock until it snaps into place. 
                

Summary of Contents for OmniCounter

Page 1: ...on 1 Table of Contents 1 Features and Benefits 1 Mounting and Orientation 2 Side Firing Mode 2 Front Firing Mode 3 Dual Directional Mode 3 Mounting Bracket 4 To Remove Sensor from bracket 5 Configuration and Powering On 6 Configuring the IR Receiver 6 To display the counts on the LCD 6 Sending a Service Packet 7 Troubleshooting 7 Appendix A Battery Replacement 8 OmniCounter Accessories 9 Features ...

Page 2: ...low Figure 1 Figure 1 shows a typical side firing door mounted installation Figure 2 shows a typical front firing wall mounted installation Figure 2 Proper Orientation Alignment is required for the counters to function properly Located on both the transmitter and receiver LCD Display side is a dimple that is used to allow the correct orientation The dimples are also used to indicate which side of ...

Page 3: ...ww trafsys com Front Firing Mode When used in Front Firing Mode the counter needs to be installed with either both dimples at the top or both dimples at the bottom Dual Directional Mode For dual mode the receiver side side with the LCD display should be mounted horizontally on the right side of the entrance with the display facing up and the dimple at the bottom The transmitter side is then mounte...

Page 4: ...ide firing the bracket will have one snap lock facing up and the other facing down to allow for proper orientation and sensor operation For dual directional mode the brackets need to be mounted horizontally Both of the brackets will have the snap lock facing the inside of the door to allow for proper orientation and sensor operation After mounting the brackets your Omni Counter sensors simply slid...

Page 5: ...dustry Drive Pittsburgh PA 15275 Page 5 of 9 Ph 888 815 6568 Fax 928 222 7279 www trafsys com To Remove Sensor from bracket To release the sensor from the mounting bracket depress the Snap lock with the included screwdriver and gently pull the top of the sensor away from the mounting bracket See Figure 4 below for the location of the Snap lock release Figure 4 ...

Page 6: ...ton on the IR Receiver If the IR Receiver and IR Transmitter are properly aligned then the LED will be lit on the IR Receiver You can exit Alignment Mode by pressing the Configuration Button again or allow it to exit Alignment Mode on its own after 60 seconds This button is also used to send a service packet This will be discussed later in the manual IR Range Low Power 0 5 Feet to 10 Feet IR Range...

Page 7: ...ED and High Power Mode is indicated by a flashing LED IR Range Low Power 0 5 Feet to 10 Feet IR Range High Power 10 Feet to 20 Feet Sending a Service Packet Sending a service packet from the OmniCounter People Counters is a useful diagnostic tool it will allow you to do the following things 1 It will allow you to easily add the sensor to your MIU data controller using the Auto Add method described...

Page 8: ...sor reads Blocked Blocked status indicates that the receiver can t see the transmitter Therefore you may need to check for these problems Make sure that there is nothing in between the sensors that is blocking it physically Check the distance between the sensors If they are approximately 12 feet apart make sure that the sensors are on high power Make sure that the transmitter side is turned on If ...

Page 9: ...path 6 If your sensors successfully generated counts congratulations you have successfully replaced the batteries in your sensors If you were unable to generate counters please refer to the Troubleshooting section of this document then contact Traf Sys Walker Wireless technical support if you require further assistance Figure 11 OmniCounter Accessories MIU 1000 or CompuCount data controller 3 6 vo...

Reviews: