![Tractel HF 87 Operating And Maintenance Instructions Manual Download Page 9](http://html.mh-extra.com/html/tractel/hf-87/hf-87_operating-and-maintenance-instructions-manual_1147585009.webp)
MS 87/./. R 03/03
9
18
CALI
(auto)
Defines the working load limit of the lifting system.
E.g. 20000 Lbs. Crane capacity. Sheaved 4/1: Cali =
20000
19
CALI
E
Press E to view this parameter .
20
20000
×
Ø
Use the arrows to correct the value to 20000
21
20000
E
Press E to confirm.
22
CALI
×
Press the UP arrows to pass the next stage.
23
StEP
(auto)
Defines the incremental step of the display
24
StEP
E
Press E to view this parameter .
25
25
×
Ø
Use the arrows to correct the value witch should be set
as the function of the accuracy required.
26
25
E
Press E to confirm.
27
StEP
×
Press the UP arrows to pass the next stage.
28
POId
(auto)
Calibrate the measurement scale compared to a well-
known load
29
POId
E
Press E to view this parameter .
30
0
(auto)
The display show the value of the load currently
suspended
31
18725
Lift an accurately known load
which should represent
at least
80% to 90% of the capacity of the lifting system,
the display indicates any incorrect value.
32
18725
E
Press E to correct this value
33
19975
×
Ø
Use the arrows to correct the value in unit of
measurement corresponding to the load actually lifted.
Our example : 19975 Lbs.
34
19975
E
Press E to confirm.
35
POId
S
Press S to return to the beginning of the sequence.
36
19975
S
Press S a second time to return to the normal display of
the load.
Calibration is completed.
Note : it is advised to repeat the calibration procedure 2
or 3 times during the first months of service in order to
correct any movement as a result of the "bending-in" of
the equipment.