TRACKMASTER
Hi-Pot Test Instructions
August 2013
TMX58 Owner’s Manual
4-1
Hi Pot Test Instructions
This test must only be performed by a qualified electrician.
Your TRACKMASTER
®
treadmill has been Hi-Pot tested at the factory just prior to
shipment and found to be within specifications. However, some facilities require Hi Pot test
verification before the treadmill is put into service. The following instructions must be
followed to prevent permanent damage to the TRACKMASTER
®
electronic control system.
Failure to follow these instructions will void your warranty.
NEVER USE AN AC HI-POT TESTER ON THIS TREADMILL
!
Using an AC HI-Pot tester will permanently damage the DC
motor controller board rendering the treadmill inoperable.
Hi-Pot test instructions for Treadmills
1.
Unplug the surge suppresser from the
main wire harness.
2.
Attach DC Hi-Pot tester ground clip to a known
chassis ground on the treadmill.
3.
For 110V models: Test at 1.75 KV DC for
60 seconds. This is equivalent to 1240
VAC.
4.
For 220V models: Test at 2.10 KV DC for
60 seconds. This is equivalent to 1488
VAC.
The tester should register a PASS for
either test.