background image

MT100 User manual

                                                                                                                       

 

 

TRACMT100UM001                                                                                                                           

- 6 - 

Revision History 

Revision 

Date 

Author 

Description of change 

V1.0.0 

2011-11-12  Lei 

Draft 

 

 

 

Summary of Contents for MT100

Page 1: ...TRACMT100UM001 GSM GPRS GPS Tracker User Manual TRACMT100UM001 Revision 1 00 GSM GPRS GPS Tracker MT100 User Manual http www TrackingTheWorld sales TrackingTheWorld com 10 TrackingTheWorld com sales TrackingTheWorld com ...

Page 2: ...e customer s possession Furthermore system validation of this product designed by TrackingTheWorld within a larger electronic system remains the responsibility of the customer or the customer s system integrator All specifications supplied herein are subject to change Copyright This document contains proprietary technical information which is the property of TrackingTheWorld copying of this docume...

Page 3: ...rview 8 2 1 Appearance 8 2 2 Parts List 9 2 3 Interface Definition 9 3 Getting Started 10 3 1 Installing a SIM Card 10 3 2 Reset Key 11 3 3 USB connector 11 3 4 Power Connection 11 3 5 Ignition Detection 11 3 6 Digital Inputs 12 3 7 Analog Inputs 13 3 8 Digital Outputs 13 3 9 Cut Relay Output 14 3 10 Device Status LED 15 ...

Page 4: ... ABBREVIATIONS 7 TABLE 3 PART LIST 9 TABLE 4 DESCRIPTION OF MT100 USER CABLE 9 TABLE 5 ELECTRICAL CHARACTERISTICS OF IGNITION DETECTION 11 TABLE 6 ELECTRICAL CHARACTERISTICS OF THE DIGITAL INPUTS 12 TABLE 7 ELECTRICAL CHARACTERISTICS OF DIGITAL OUTPUT 13 TABLE 8 DEFINITION OF DEVICE STATUS AND LED 16 ...

Page 5: ...0 8 FIGURE 2 SIM CARD INSTALLATION 10 FIGURE 3 TYPICAL POWER CONNECTION 11 FIGURE 4 TYPICAL IGNITION DETECTION 12 FIGURE 5 TYPICAL DIGITAL INPUT CONNECTION 13 FIGURE 6 TYPICALANALOG INPUT CONNECTION 13 FIGURE 7 TYPICAL CONNECTION WITH RELAY 14 FIGURE 8 MT100 LED ON THE CASE 15 ...

Page 6: ...MT100 User manual TRACMT100UM001 6 Revision History Revision Date Author Description of change V1 0 0 2011 11 12 Lei Draft ...

Page 7: ...y or scheduled GPS position as well as many other useful functions Users can also use MT100 to monitor the status of a vehicle and control the vehicle by its external relay output System Integrators can easily setup their tracking systems based on the full featured Track protocol This device complies with part 15B part 22 and part 24 of the FCC rules Operation is subject to the following two condi...

Page 8: ...MT100 User manual TRACMT100UM001 10 2 Product Overview 2 1 Appearance Figure 1 Appearance of MT100 ...

Page 9: ...ow Relay ouput1 8 Yellow Relay ouput2 Table 3 Part List Picture mm User Cable which contain the connection for power ignition input digital input analog input siren output cut output etc The user cable s Table 4 Description of MT100 User Cable Description Comment External DC power input 8 32V System ground connect to the vehicle s frame directly Ignition input positive trigger Digital input negati...

Page 10: ...hods to Power on MT100 MT100 external power turned on Connect MT100 to PC with user cable When the external power or USB cable power be removed MT100 will switch to internal backup battery and keep on running When internal backup battery is exhausted MT100 will give a report and then turn off Note 1 External power and User USB power can be present at same time 2 For USB port current limitation whe...

Page 11: ...here is a USB connector on MT100 which is beside the SIM card With the USB connector and the DATA_CABLE_M user can configure the system or download firmware As long as the DATA_CABLE_M is plugged in the system will boot 3 5 Power Connection The red wire is power wire and the black wire is ground wire The input voltage range for this device is from 8V to 32V The device is designed to be installed i...

Page 12: ...he power source for the FM radio Ignition signal can be configured to start transmitting information to backend server when ignition is on and enter power saving mode when ignition is off 3 7 Digital Inputs There is a general purpose digital input which is the blue wire on MT100 User Cable and it is a negative trigger The digital input is recommended to support panic button function Table 6 Electr...

Page 13: ...ction Figure 6 Typical Analog Input Connection 3 9 Digital Outputs There is an output which is the brown wire on MT100 User Cable This output is used to drive a siren and the maximum drive current is 750mA When the siren output is enabled the voltage on the siren output is determined by the system power level if the system power is 12V then the siren output voltage is 12V Table 7 Electrical Charac...

Page 14: ...in cut relay on MT100 and it is a NO type relay which maximum switching voltage is 16VDC and maximum continuous current is 30A On MT100 user cable one 18AWG yellow wire is connected to the cut relay NO contact and the other 18AWG yellow wire is connected to the cut relay COM contact In certain instances the two wires will be connected together ...

Page 15: ...MT100 User manual TRACMT100UM001 12 3 11 Device Status LED Figure 8 MT100 LED on the Case ...

Page 16: ... network Fast flashing Note3 Device has registered to GSM network Slow flashing Note4 SIM card needs pin code to unlock ON GPS note 2 GPS chip is powered off OFF GPS sends no data or data format error Slow flashing GPS chip is searching GPS info Fast flashing GPS chip has gotten GPS info ON PWR note 2 No external power and internal battery voltage is lower than 3 35V OFF No external power and inte...

Reviews: