MT100 User manual
TRACMT100UM001
-12 -
Inactive
0V to 3V or Open
Figure 4.
Typical Ignition Detection
The white wire is used for ignition detection. It is strongly recommended to connect this
wire to ignition key “RUN” position as shown up.
An alternative to connecting to the ignition switch is to find a non permanent power source
that is only available when the vehicle is running. For example the power source for the
FM radio.
Ignition signal can be configured to start transmitting information to backend server when
ignition is on; and enter power saving mode when ignition is off.
3.7.
Digital Inputs
There is a general purpose digital input which is the blue wire on MT100 User Cable, and
it is a negative trigger. The digital input is recommended to support panic button function.
Table 6: Electrical Characteristics of the digital inputs
Logical State
Electrical Characteristics
Active
0V to 0.8V
Inactive
Open
The following diagram shows the recommended connection of the digital input.