- 11 -
IGN (Pin4) is used for ignition detection. It is recommended to connect this pin to
the “RUN” position
of the vehicle ignition switch as shown below.
An alternative to connect to the ignition switch is to find a non-permanent power source that is only
available when the vehicle is running. For example, the power source for the FM radio.
IGN signal can be configured to transmit information to the backend server when ignition is on and
enter power saving mode when ignition is off
Table 5.
AVL50 4G Electrical Characteristics of Ignition Detection
Logical State
Electrical Characteristics
Active
5.0V to 32V
Inactive
0V to 3V or Open loop
Figure 4.
Typical Power Connection
OUT1/IN1 (PIN5) is a digital Output/Input on AVL50 4G. It is of open drain type and the maximum
drain current is 150mA. The OUT1/IN1 (PIN5) can be used either as a digital output or a (positive and
negative trigger) digital input
Figure 5.
Digital Output Internal Drive Circuit
2.5.
Ignition Detection
2.6.