5.5 SSI
5.5.1 Counts SSI-Bits
The parameter
Number of data bits
defines the number of reserved bits for the
measuring system position.
lower limit
12
upper limit
31
default
24
5.5.2 SSI-Code
Selection
Description
Default
Binary
SSI output code = Binary
Gray
SSI output code = Gray
X
5.5.3 SSI-Frequency Master-Mode
If the adapter is used as SSI master, with this parameter the SSI transfer rate can be
set.
Selection
Description
Default
750 kHz
SSI transfer rate 750 kHz
400 kHz
SSI transfer rate 400 kHz
250 kHz
SSI transfer rate 250 kHz
X
200 kHz
SSI transfer rate 200 kHz
125 kHz
SSI transfer rate 125 kHz
5.5.4 SSI-Cycle Master-mode
If the adapter is used as SSI master, with this parameter the SSI cycle time can be
set.
Selection
Description
Default
300
s
SSI cycle time 300
s
400
s
SSI cycle time 400
s
500
s
SSI cycle time 500
s
X
1 ms
SSI cycle time 1 ms
2 ms
SSI cycle time 2 ms
5 ms
SSI cycle time 5 ms
10 ms
SSI cycle time 10 ms