5.2.1 Basic settings
Start TRWinProg on the PC and select the menu “
Extra --> Global
”.
Select the button
rig
ht hand in the window at “
USB-HID
“ to show the available
HID devices and the serial COM ports.
Choose the “
HID-Device
“ with a double click on the left mouse button. The HID
device address is displayed then in the window. If the depending HID device is
already active, it
can’t be selected again. In this case, this window must be closed
and the window “
Global
” must be opened again.
In the drop-
down menu “
Comm-DLL : TRWPDLL
“, the selection „
HID-Device
“
must be set automatically.
On top of the window at the
menu “
USB-HID
” it can be selected which HID-device
shall be accessed.
Maximum 7 adapters can be connected at a PC. Therefore the HID device
addresses from 0xA361 to 0xA367 are available. The HID device address can be
changed afterwards about the parameter "Low-Address HID-Device", see page
28.
To save the settings you have to press the „
OK
“ button.
With the „
Offline <--> Online
“ button
the PC-Adapter now can be
connected.