![TR-Electronic CDH582 User Manual Download Page 34](http://html1.mh-extra.com/html/tr-electronic/cdh582/cdh582_user-manual_1146691034.webp)
Commissioning
TR-Electronic GmbH 2020, All Rights Reserved
Printed in the Federal Republic of Germany
Page 34 of 91
TR-ECE-BA-GB-0163 v03
10/07/2020
4.3 Bus status display
The measuring system is equipped with bicolor diagnostic LEDs. A self-test is performed when the
system is switched on and indicated by the red/green flashing (1 Hz) module status LED.
For safety reasons, status LEDs may only be used for general diagnosis during
commissioning and troubleshooting but may not be used as an operational display!
Figure 9: Measuring system diagnostic LEDs
LED1: Module status “Mod Stat”
green
Description
Off
– Voltage supply missing or too low
– Hardware error, measuring system defective
On
Measuring system ready for operation (no error)
1 Hz
The measuring system is in Idle state
red
Description
On
a critical error has occurred
1 Hz
The measuring system is in Abort state
red/green Description
red <-> green
1 Hz
The measuring system performs a self-test or must be configured
LED2: Network status “Net Stat”
green
Description
Off
– Voltage supply missing or too low
– Hardware error, measuring system defective
– Measuring system offline
On
Measuring system online, CIP connection established
1 Hz
Measuring system online, CIP connection not established