3.4.2.2 Cable lengths
SSI clock frequency and cable quality determine the maximum cable length.
TR’s own hybrid cable (part number: 64-200-021) was used for the measurements.
SSI clock frequency [kHz]
1000
500
250
125
125
125
Cable length [m]
ca. 25
ca. 50
ca. 100
ca. 150
ca. 200
ca. 250
Table 1
:
SSI clock frequency / cable lengths
Figure 7: SSI clock frequency / cable lengths
Other cable parameters, frequencies, and ambient temperatures as well as bearing heat and
temperature increase via the shaft and flange, can yield a considerably poorer result in practice.
Therefore, the fault-free function of the SSI interface with the application-dependent parameters must
be checked prior to productive operation.