Product Code: 1031T  

 

             

                      Made in China to TQB Brands Pty Ltd specifications 

Page 6 

 

 

Visit us at www.tqbbrands.com.au 

 
 
Minimum Clearance 
When the appliance is running, ensure the filter screen and the cold air ducting are 300mm 
minimum from the wall or other obstacles, and the hot exhaust pipe is 900mm minimum 
from the ceiling or other obstacles. 
 
 
 
 

 
Adjustment Air Range 
The cold air duct can rotate left or right to 360degrees (hot air exhaust duct is installed) 
The cold air duct may be moved up or down to 150degrees 
The range of adjustment angle for the hot air exhaust duct is 45degrees 
 

 

  

WARNING -Adjust the cold air duct prior to use and adjust the air out direction of the 

hot exhaust duct later.  
When adjusting the flow angle of the cold air duct, grip the elbow for adjustment – do not 
hold on to the cold air duct directly. 

 
Condensation Tank 
A  5Litre  polyethylene  condensation  tank  in  the  lower-front  compartment  of  the  unit 
collects evaporator-coil condensation moisture. When full, simply remove, drain, replace, 

and restart. Do not move the machine if the condensation tank is full of water. 
To empty the water in the condensation tank, ensure the end face on the tank handle is 
parallel.  Rotate  the  control  switch  to  0.  Empty  the  water  in  a  resourceful  manner  and 

reinstall the condensation tank before restarting Air Conditioner. 
 
 
 

 
Pipe Drain (optional)
 
Condensation water may be discharged directly from the Air Conditioner drain pipe. 
 
Remove the water tank and empty, push the optional drain pipe on to the appliance outlet 
inside  the  tank  recess.  Then  locate  the  drain  pipe  through  the  round  hole  in  the 
corresponding side plate. Ensure the end of the pipe is below the Air Conditioner. 
 
 
 

 
 
Compressor Overload/Overheat Protection
 
The compressor overload protector will be activated to cut the power of the compressor to “Off” in the event of overly high 
or low voltage and/or overly high temperatures. 
When the overload protector is activated, the machine will only blow non-refrigerated air.  
Contact a qualified service technician if the overload protector is activated frequently. 
 

 

4.

 

MAINTENANCE 

Disconnect power prior to any maintenance 
Inspect the general condition of the Air Conditioner checking:  

 

for loose hardware 

 

cracked, bent, or broken parts, and 

 

any other condition that may affect the Air Conditioners safe operation 

 

Filter Screen 
Clean the  filter screen regularly  using a  vacuum  cleaner to remove dust and dirt.  When required the  filter screen  can be 
cleaned with a cloth and luke warm water.  Do not use chemicals. Leave to dry in a shaded area before reinstalling. 
NOTE: For effective cooling clean the filter at least every 2 weeks. 

Fig11.

Fig10.

Summary of Contents for TradeQuip 1031T

Page 1: ...t Code 1031T Made in China to TQB Brands Pty Ltd specifications Visit us at www tqbbrands com au Product Code 1031T AIR CONDITIONER Specifications Cooling Capacity 2 7KW 9200Btu Power Unit 240V 50Hz R...

Page 2: ...how this equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and proper...

Page 3: ...allow chemical substances to come into contact with the unit 20 DO NOT operate the unit in the presence of flammable substances or vapours such as alcohols pesticides gasoline etc DO NOT use the plug...

Page 4: ...models are equipped standard with heavy duty castors for easy portability TradeQuip Portable Industrial Air Conditioners bring in air from an outside source to cool its condenser cycling hot air to a...

Page 5: ...uitable fixing tape The outdoor heat extraction duct must be water proof and protected from external debris falling into the exhaust duct point pipe downwards 3 OPERATION 1 Unlock the castors wheels a...

Page 6: ...ty the water in a resourceful manner and reinstall the condensation tank before restarting Air Conditioner Pipe Drain optional Condensation water may be discharged directly from the Air Conditioner dr...

Page 7: ...ir Conditioner is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels spe...

Page 8: ...ove 4 50 Condensation Tray 1 9 Control Knob 1 30 Heat Exchange Assembly 1 51 Tank Cover Plate 1 10 Control Panel Label 1 31 Cold Outlet Pipe Assembly 2 52 Drain Pipe 1 11 Control Box 1 32 High Pressur...

Page 9: ...of charge This guarantee does not apply to normal wear and tear nor does it cover any damage caused by misuse careless or unsafe handling alterations accident or repairs attempted or made by any pers...

Reviews: