STANDARD OPERATING PROCEDURE 

AIRCONDITIONER 

DO NOT use this machine unless you have been trained and assessed to a competent level in its sate use and operation, and 
have been given permission to use this  

 

 

OPERATIONAL SAFETY CHECKS 

 

1.

 

Do not use this Air Conditioner in areas that use or store volatile substances (gasoline, kerosene, liquefied gas and other 
volatile liquids; magnesium, aluminium, lead and other volatile dust and/or vapours) to avoid possible ignition, explosion 
or fire. 

2.

 

Servicing must be carried out by a qualified service technician.  Use only TradeQuip identical replacement parts. Use of 
any other parts will void the warranty.  Ensure the Air Conditioner is disconnected from power before servicing. 

3.

 

Use  the  right  product  for  the  job.  There  are  certain  applications  for  which  the  Air  Conditioner  was  designed.  Do  not 
modify the Air Conditioner and do not use the Air Conditioner for a purpose for which it was not intended.  

4.

 

Always disconnect the Air Conditioner when moving it from one location to another. 

5.

 

Transport and store the unit in an upright position only. Leave unit in an upright position for at least 3 hours before first 
use. 

6.

 

Always place the unit on an even, level surface. 

7.

 

Ensure the unit is connected to a grounded power supply of the correct rating / capacity. 

8.

 

The  unit  will  cool  when  the  room  temperature  is  between  18°C  (64.4°F)  ~  45°C(113°F)  depending  on  the  thermostat 
setting. 

9.

 

DO NOT use this unit for functions other than those described in this instruction manual. 

10.

 

DO NOT tilt the unit. Only use in the upright position on an even, flat surface. Unit must be positioned at least 600mm 
from the nearest object in any direction 

11.

 

Ensure 240V mains power supply. 

12.

 

Use within temperature range of 18°C ~45°C 

13.

 

This Air Conditioner is intended for indoor use only. 

14.

 

DO NOT cover or obstruct the unit's inlet and outlet grills or ducting. 

15.

 

DO NOT use the unit in areas where it will be exposed to rain or water. 

16.

 

NEVER unplug the unit while it is operating. 

17.

 

DO NOT place any foreign objects on the unit. 

18.

 

DO NOT operate the unit with wet or damp hands. 

19.

 

DO NOT allow chemical substances to come into contact with the unit. 

20.

 

DO NOT operate the unit in the presence of flammable substances or vapours such as alcohols, pesticides, gasoline, etc. 
DO NOT use the plug to start and to stop the unit. Always use the control panel to start and to stop the unit. 

21.

 

Always turn off the unit when it is not in use and unplug the power plug from the electrical outlet. 

22.

 

Always turn the unit off and unplug the main power plug from the electrical outlet before cleaning, moving or performing 
maintenance. 

23.

 

AVOID the use of adaptor plugs or extension cords. If it is necessary to use an extension cord or an adaptor plug to operate 
the unit, ensure that they are correctly rated for the application. Consult a local qualified electrician and all local electrical 
codes to ensure proper setup. Any extension cord used with this device must be rated for a minimum of 30A. 

24.

 

DO  NOT  unplug  the  unit  by  pulling  on  the  electrical  cord.  Keep  electrical  cord  away  from  heat  sources  and  always 
completely unroll the cord to avoid overheating. If the power cord becomes damaged, a qualified service agent, qualified 
electrician, or similarly qualified person must replace it, in order to avoid a hazard or shock.  

25.

 

The filters must be used with the product at all times. When the filters are removed for cleaning, always ensure that the 
unit has been turned off and unplugged from the electrical outlet. 

26.

 

DO NOT operate the unit with a damaged power cord or plug, after it malfunctions, has been dropped or damaged. 

27.

 

Regularly clean the filters to maintain efficiency. If the filters are not cleaned regularly, the unit’s output performance 
and efficiency will decline and energy consumption will increase. 

28.

 

Stop operation immediately if abnormal noise or odour is noticed. Contact a local service centre. 

29.

 

This appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision or instruction. 

30.

 

This appliance must be installed in accordance with state and/or national wiring regulations. 

31.

 

If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 
electrician in order to avoid a hazard. 

 

DO NOT tilt the unit 

 

Close fitting/protective clothing must be worn 
when operating this equipment 

 

DO NOT operate the unit with wet or damp 
hands 

 

 

Summary of Contents for TradeQuip 1031T

Page 1: ...t Code 1031T Made in China to TQB Brands Pty Ltd specifications Visit us at www tqbbrands com au Product Code 1031T AIR CONDITIONER Specifications Cooling Capacity 2 7KW 9200Btu Power Unit 240V 50Hz R...

Page 2: ...how this equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and proper...

Page 3: ...allow chemical substances to come into contact with the unit 20 DO NOT operate the unit in the presence of flammable substances or vapours such as alcohols pesticides gasoline etc DO NOT use the plug...

Page 4: ...models are equipped standard with heavy duty castors for easy portability TradeQuip Portable Industrial Air Conditioners bring in air from an outside source to cool its condenser cycling hot air to a...

Page 5: ...uitable fixing tape The outdoor heat extraction duct must be water proof and protected from external debris falling into the exhaust duct point pipe downwards 3 OPERATION 1 Unlock the castors wheels a...

Page 6: ...ty the water in a resourceful manner and reinstall the condensation tank before restarting Air Conditioner Pipe Drain optional Condensation water may be discharged directly from the Air Conditioner dr...

Page 7: ...ir Conditioner is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels spe...

Page 8: ...ove 4 50 Condensation Tray 1 9 Control Knob 1 30 Heat Exchange Assembly 1 51 Tank Cover Plate 1 10 Control Panel Label 1 31 Cold Outlet Pipe Assembly 2 52 Drain Pipe 1 11 Control Box 1 32 High Pressur...

Page 9: ...of charge This guarantee does not apply to normal wear and tear nor does it cover any damage caused by misuse careless or unsafe handling alterations accident or repairs attempted or made by any pers...

Reviews: