background image

led IndIcatorS

Strobe 

LED indicator

Power 

LED indicator

connectIon

WIrIng

M12 Connector

 

5 male points

+ 24 V

1

2

3

4

Ground
PNP

5

Dim 0-10V

STROBE 

PNP

 :

+ 24 V
NPN

1

2

3

4

Ground

STROBE 

NPN

 :

+ 24 V

1

2

3

4

Ground
PNP

+ 24 V
NPN

1

2

3

4

Ground

CONTINUOUS

 MODE :

or

2

4

1

+ 24 V

3

GND

5

DIM 0-10V

STROBE

NPN

STROBE

PNP

5

Dim 0-10V

5

Dim 0-10V

5

Dim 0-10V

black

brown

blue

grey

white

front view

top view

P3/8

Summary of Contents for M-EBAR

Page 1: ...s must be followed at all times TPL Vision will not be held responsible for problems caused by using the product contrary to these instructions and the Warranty will be deemed invalid unpacking This product is packed at the factory using suitable materials for safe transport To open the package do not use any cutting blade to avoid damaging the product s Please use the delivered accessories if nee...

Page 2: ...not supplied During the set up the light has to be switched off and unplugged Please use M4 screws and insert them in the captive nuts located in the back of the light The light will be better fixed if you spread the attachment points symmetrically along the bar You can also use M4 screws not supplied fastened directly into Aluminium profile with a tightening torque from 0 5 to 1 5 Nm We also reco...

Page 3: ...5 male points 24V 1 2 3 4 Ground PNP 5 Dim0 10V STROBEPNP 24V NPN 1 2 3 4 Ground STROBENPN 24V 1 2 3 4 Ground PNP 24V NPN 1 2 3 4 Ground CONTINUOUSMODE or 2 4 1 24V 3 GND 5 DIM0 10V STROBE NPN STROBE PNP 5 Dim0 10V 5 Dim0 10V 5 Dim0 10V black brown blue grey white Front view Top view P3 8 ...

Page 4: ...tmosphere In strobe mode the strobing time is directly equivalent to the time during which the strobe entry is activated Strobe PNP NPN PNP from 5 to 24V for 100 ON From 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Brightness D max t max f max 100 N A CW N A 100 to 240 1 5 30 ms 30Hz D Duty Cycle t pulse duration f frequency operatingConditions 10 to 40 C 14 to 104 ...

Page 5: ... mode Please consider a tolerance of 5 when measuring the dimmed bri ghtness levels STROBE INPUT STROBE INPUT STROBE INPUT 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 240 100 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 100 After 30ms LED are supplied at 100 level LED are supplied with 240 maximum current After 30ms LED are supp...

Page 6: ...nstallation to minimise operator exposure to the light source Installation Guidance Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter to prevent the operators from approaching the lighting source beyond the recom mendations of the manufacturer If the workstation permits it introduce a filter that will stop the lighting radiatio...

Page 7: ... Cleaning when the product is switched off Please use a soft and dry cloth Do not use any abrasive material Do not use any cleaning solvent or aggressive chemical product TPL Vision recommends to use isopropyl alcohol P7 8 ...

Page 8: ...I S O 9 0 0 1 CERTIFIED MANUFACTURER 44 0 1738 310 392 contact tpl vision co uk Brenchley House School Road Charing Kent TN27 0JW United Kingdom Features and presentations liable to changes without notice Ref UG 010801 E2 2021 10 edition ...

Reviews: