background image

* Total length, without connector.

dImenSIonS

Length 

(mm)

Height 

(mm)

Width 

(mm)

A

B

C

M-EBAR 125

158

45

47.6

M-EBAR 250

283

45

47.6

M-EBAR 375

408

45

47.6

M-EBAR 500

533

45

47.6

USer gUIde

P2/8

n

  Length (Lg) < 500 mm: 2 captive nuts M4

n

  500 mm ≤ Lg < 1000 mm: 4 captive nuts M4

n

  1000 mm ≤ Lg ≤ 1250 mm: 6 captive nuts M4

fIxIng

(supplied)

Captive nuts

Screw M4

(not supplied)

During the set up, the light has to be switched off and unplugged. Please 
use M4 screws and insert them in the captive nuts located in the back of 
the light. The light will be better fixed if you spread the attachment points 
symmetrically along the bar.

You can also use M4 screws (not 
supplied) fastened directly into 
Aluminium profile with a tightening 
torque from 0.5 to 1.5 Nm. We also 
recommend the use of a thread-
locker (not supplied) to avoid any 
risk of loosening.

Please use all the captive nuts. NeveR ReMove theM fRoM the baR.

Summary of Contents for M-EBAR

Page 1: ...s must be followed at all times TPL Vision will not be held responsible for problems caused by using the product contrary to these instructions and the Warranty will be deemed invalid unpacking This product is packed at the factory using suitable materials for safe transport To open the package do not use any cutting blade to avoid damaging the product s Please use the delivered accessories if nee...

Page 2: ...not supplied During the set up the light has to be switched off and unplugged Please use M4 screws and insert them in the captive nuts located in the back of the light The light will be better fixed if you spread the attachment points symmetrically along the bar You can also use M4 screws not supplied fastened directly into Aluminium profile with a tightening torque from 0 5 to 1 5 Nm We also reco...

Page 3: ...5 male points 24V 1 2 3 4 Ground PNP 5 Dim0 10V STROBEPNP 24V NPN 1 2 3 4 Ground STROBENPN 24V 1 2 3 4 Ground PNP 24V NPN 1 2 3 4 Ground CONTINUOUSMODE or 2 4 1 24V 3 GND 5 DIM0 10V STROBE NPN STROBE PNP 5 Dim0 10V 5 Dim0 10V 5 Dim0 10V black brown blue grey white Front view Top view P3 8 ...

Page 4: ...tmosphere In strobe mode the strobing time is directly equivalent to the time during which the strobe entry is activated Strobe PNP NPN PNP from 5 to 24V for 100 ON From 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Brightness D max t max f max 100 N A CW N A 100 to 240 1 5 30 ms 30Hz D Duty Cycle t pulse duration f frequency operatingConditions 10 to 40 C 14 to 104 ...

Page 5: ... mode Please consider a tolerance of 5 when measuring the dimmed bri ghtness levels STROBE INPUT STROBE INPUT STROBE INPUT 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 240 100 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 30 ms 30 ms 15 µs 15 µs LIGHT Triggering input 30 ms 100 After 30ms LED are supplied at 100 level LED are supplied with 240 maximum current After 30ms LED are supp...

Page 6: ...nstallation to minimise operator exposure to the light source Installation Guidance Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter to prevent the operators from approaching the lighting source beyond the recom mendations of the manufacturer If the workstation permits it introduce a filter that will stop the lighting radiatio...

Page 7: ... Cleaning when the product is switched off Please use a soft and dry cloth Do not use any abrasive material Do not use any cleaning solvent or aggressive chemical product TPL Vision recommends to use isopropyl alcohol P7 8 ...

Page 8: ...I S O 9 0 0 1 CERTIFIED MANUFACTURER 44 0 1738 310 392 contact tpl vision co uk Brenchley House School Road Charing Kent TN27 0JW United Kingdom Features and presentations liable to changes without notice Ref UG 010801 E2 2021 10 edition ...

Reviews: