TPI 6300/T Series Operating Instructions Manual Download Page 6

 

Unit  

Length 

Volts 

PH. 

Item 

Part No. 

Description 

Qty 

33” 

208 

3/1 

52275001 

208V  1KW Heating Element 

Π

 

240 

3/1 

52275002 

240V 1KW Heating Element 

277 

52275003 

277V 1KW Heating Element 

415 

52275002 

240V 1KW Heating Element 

480/277 

3/1 

52275003 

277V 1KW Heating Element 

480 

ΠΠ

Π

 

52275004 

480V 1KW Heating Element 

600 

52275013 

2,4&6KW-300V 1KW Heating Element 

52275014 

3&5KW-347V 1KW Heating Element 

52275013 

2&4KW-300V 1KW Heating Element 

52275014 

3,5&6KW-347V 1KW Heating Element 

46” 

208 

3/1 

52275005 

208V  2KW Heating Element 

Π

 

240 

3/1 

52275006 

240V 2KW Heating Element 

277 

52275007 

277V 2KW Heating Element 

415 

52275006 

240V 2KW Heating Element 

480/277 

3/1 

52275007 

277V 2KW Heating Element 

480 

ΠΠ

Π

 

52275008 

480V 2KW Heating Element 

600 

3/1 

52275012 

600V 2KW Heating Element 

All Units 

60149051 

Linear Safety Limit 

44067001 

Manual Reset Limit 

1

Π

Π

 

 

 

PARTS VIEW AND PARTS LIST (CONTINUED) 

ISSUE DATE 06/15/01          REV. DATE  

REV. NO. 00          EC0 NO. 1-4635      P/N 00009979                SHT. 06 OF 09 

Unit 

Length 

Volts 

Phase 

Item 

Part No. 

Description 

Qty 

33” 

208/240 

3/1 

52289001 

208/240V Motor single shaft 

415 

3-4wire 

52289001 

208/240V Motor single shaft 

277 

52289003 

277V Motor single shaft 

480 

3-3wire/1 

52289004 

480V Motor single shaft 

480 

3-4wire 

52289003 

277V Motor single shaft 

600 

3/1 

52289005 

575V Motor single shaft 

All 

3/1 

62441001 

Blower wheel 

46” 

208/240 

3/1 

52290001 

208/240V Motor Double shaft 

415 

3-4wire 

52290001 

208/240V Motor Double shaft 

277 

52290003 

277V Motor Double shaft 

480 

3-3wire/1 

52290004 

480V Motor Double shaft 

480 

3-4wire 

52290003 

277V Motor Double shaft 

600 

3/1 

52290005 

575V Motor Double shaft 

All 

3/1 

62441001 

Blower wheel 

66” 

208/240 

3/1 

52289001 

208/240V Motor single shaft 

415 

3-4wire 

52290001 

208/240V Motor double shaft 

277 

52289003 

277V Motor single shaft 

52290003 

277V Motor double shaft 

480 

3-3wire/1 

52289004 

480V Motor single shaft 

52290004 

480V Motor double shaft 

480 

3-4wire 

52289003 

277V Motor single shaft 

52290003 

277V Motor double shaft 

600 

3/1 

52289005 

575V Motor single shaft 

52290005 

575V Motor double shaft 

All 

3/1 

62441001 

Blower wheel 

79” 

208/240 

3/1 

52290001 

208/240V Motor double shaft 

415 

3-4wire 

52290001 

208/240V Motor double shaft 

277 

52290003 

277V Motor double shaft 

480 

3-3wire/1 

52290004 

480V Motor double shaft 

480 

3-4wire 

52290003 

277V Motor double shaft 

600 

3/1 

52290005 

575V Motor double shaft 

All 

3/1 

62441001 

Blower wheel 

 

66 and 79 inch units are Custom 
Specified Cabinets Unit Heaters 

Heat Deck Assembly 

Blower Deck Assembly 

NOTE: 1. 66” Units use the following sizes of Heat/Blower deck assemblies. 

A) Qty.1 ea.-33 
B) Qty. 1 ea.-46” 

            2. 79” Units have (2) 46” Heat/Blower deck assemblies. 
        

Π

Quantity varies with KW 

ΠΠ

All except for the following 66” and 79” 3-phase units: which have Qty. 2 

       208V – 16KW thru 24KW 
       240V – 20KW thru 24KW 

ΠΠΠ

Both 2-Wire, 3-Wire and 4-Wire systems.

 

Summary of Contents for 6300/T Series

Page 1: ...bs 4 thru 12KW Heater W66 H25 D9 1 2 215lbs 6 thru 18KW Heater W79 H25 D9 1 2 248lbs 8 thru 24KW Heater SPECIFICATIONS Read all instructions before using this heater 1 Follow all local and electrical codes the National Electric code NEC and the Occupational Safety and Health Act OSHA 2 Before attempting any electrical connections or inspections for any reason to service the heater make sure that t...

Page 2: ... and 600 volt 3 phase units are all single speed only If external load management control of the unit is desired replace factory installed jumper wire on the control terminal block with leads from the external management control Refer to page 7 for description of control options OPERATING INSTRUCTIONS SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Heater does not energize 1 Defective thermostat 2 Defe...

Page 3: ...es are indicated for each mounting configuration In all positions clearance from end of heater to a side wall is zero inches Mounting holes are provided in the back of the cabinet accessible through the blower compartment If necessary remove blower deck if additional mounting screws or bolts are desired Blower deck may be slipped forward by loosening four screws at the front to provide access to m...

Page 4: ...s are provided in the back of the wiring compartment Make sure all field wiring connections are properly made and are tight Electrical Ground This heater must be grounded before operating as required by the National Electric Code and by applicable local codes Use a conductor of the appropriate size secured to the ground lug in the heater and to a grounded connection in the service panel Typical Wi...

Page 5: ...1 58027001 60719037 51135006 58027002 41017001 277 1 480 3 4 wire 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719011 51135006 58027002 41017009 480 1 480 3 3 wire 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719012 51135006 58027002 41017001 600 3 1 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719040 51135006 58027002 5834...

Page 6: ...001 Blower wheel 1 46 208 240 3 1 1 52290001 208 240V Motor Double shaft 1 415 3 4wire 52290001 208 240V Motor Double shaft 277 1 52290003 277V Motor Double shaft 480 3 3wire 1 52290004 480V Motor Double shaft 480 3 4wire 52290003 277V Motor Double shaft 600 3 1 52290005 575V Motor Double shaft All 3 1 2 62441001 Blower wheel 2 66 208 240 3 1 1 52289001 208 240V Motor single shaft 1 415 3 4wire 52...

Page 7: ...re operated by and internal 24 volt source B4 Built in single stage thermostat and relays which are operated by an internal 120 volt source also includes fusing in the fan circuit and the transformer primary B5 Built in two stage thermostat and relays which are operated by and internal 24 volt source B6 Built in two stage thermostat and relays which are operated by an internal 120 volt source also...

Page 8: ...NS ISSUE DATE 06 15 01 REV DATE REV NO 00 ECO NO 1 4635 P N 00009979 SHT 08 OF 09 ΠComes factory wired as a 3 phase unit can be field converted to single phase ΠΠcomes factory wired as 480V 3 phase 4 wire unit can be field converted to 277V single phase T 46 D 08 24 1 2 B3 S C M F D P A B C D E F G H I J K L M N A Series designation T B Cabinet size 33 33 in 46 46 in 66 66 in or 79 79 in C Inlet o...

Page 9: ...1 73 14 12 25 12 9 39 14 10 5 10 6 49 98 6 43 57 6 37 70 6 21 79 10 17 45 10 35 06 8 30 68 8 16 66 10 15 35 12 15 87 12 12 28 12 12 6 12 6 59 59 4 51 90 6 44 92 6 25 95 8 20 78 10 35 06 8 30 68 8 18 56 10 15 35 12 15 87 12 12 28 12 66 6 2 2 6 3 1550 1400 31 75 8 27 90 8 24 12 8 13 95 12 11 29 14 27 58 8 24 29 8 12 25 12 14 32 12 9 82 14 9 Π3 3 9 6 46 17 6 40 40 8 34 99 8 20 20 10 16 29 12 27 58 8 ...

Page 10: ...ion trim fr trim fr trim fr trim fr trim frames are for decor ames are for decor ames are for decor ames are for decor ames are for decora a a a a tive use onl tive use onl tive use onl tive use onl tive use only they are y they are y they are y they are y they are not not not not not made for supporting the cabinet unit hea made for supporting the cabinet unit hea made for supporting the cabinet ...

Page 11: ...ns or limitations may not apply to you During the warranty period TPI Corporation will at its sole option repair or replace any defective parts or products returned freight prepaid to the TPI Corporation factory or such other locations as TPI Corporation may designate Returned products must be packaged carefully and TPI Corporation shall not be responsible for damage in transit When returning part...

Reviews: