TPI 6300/T Series Operating Instructions Manual Download Page 3

ISSUE DATE 06/15/01       REV. DATE  

         REV. NO. 00          ECO NO. 1-4635       P/N 00009979                      SHT. 03 OF 09 

MOUNTING CONFIGURATIONS 

 

All Angle Heater Series offers a selection of air inlet and discharge arrangements.  
Inlet and outlet grille arrangements are easily altered  by opening front panel of unit 
and removing (2) screws. 

Heaters Cannot be 
mounted on the  
END! 

 

NOTE:  Semi recessed to be recessed  
              3 ½ “  maximum unless both 
              inlet and outlet grilles are to the   
              front.

 

SEMI RECESSED 

FULLY RECESSED 

SEMI RECESSED 

SEMI RECESSED

 

MOUNTING CLEARANCES 

Proper clearances are indicated for each mounting configuration.  In all positions, 
clearance from end of heater to a side wall is zero inches. 
 
Mounting holes are provided in the back of the cabinet, accessible through the blower 
compartment.  If necessary, remove blower deck if additional mounting screws or 
bolts are desired.  Blower deck may be slipped forward by loosening four screws at 
the front to provide access to mounting holes. 

KEY 

6” minimum 

12”minimum 

0 or greater 

24”minimum 

48”minimum 

UP FLOW 

DOWN FLOW 

Unit may be mounted upside down to 
reverse direction of air flow. 

A

B

W

C

D

Y

A

D

W

Y

D

Y

A

C

Z

B

D

X

A

Z

X

D

D

X

A

W

V

W

B

V

C

Y

V

Y

V

D

W

A

V

D

Y

V

D

Y

V

 

UP FLOW 

WALL 

CEILING 

DOWN FLOW 

Summary of Contents for 6300/T Series

Page 1: ...bs 4 thru 12KW Heater W66 H25 D9 1 2 215lbs 6 thru 18KW Heater W79 H25 D9 1 2 248lbs 8 thru 24KW Heater SPECIFICATIONS Read all instructions before using this heater 1 Follow all local and electrical codes the National Electric code NEC and the Occupational Safety and Health Act OSHA 2 Before attempting any electrical connections or inspections for any reason to service the heater make sure that t...

Page 2: ... and 600 volt 3 phase units are all single speed only If external load management control of the unit is desired replace factory installed jumper wire on the control terminal block with leads from the external management control Refer to page 7 for description of control options OPERATING INSTRUCTIONS SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Heater does not energize 1 Defective thermostat 2 Defe...

Page 3: ...es are indicated for each mounting configuration In all positions clearance from end of heater to a side wall is zero inches Mounting holes are provided in the back of the cabinet accessible through the blower compartment If necessary remove blower deck if additional mounting screws or bolts are desired Blower deck may be slipped forward by loosening four screws at the front to provide access to m...

Page 4: ...s are provided in the back of the wiring compartment Make sure all field wiring connections are properly made and are tight Electrical Ground This heater must be grounded before operating as required by the National Electric Code and by applicable local codes Use a conductor of the appropriate size secured to the ground lug in the heater and to a grounded connection in the service panel Typical Wi...

Page 5: ...1 58027001 60719037 51135006 58027002 41017001 277 1 480 3 4 wire 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719011 51135006 58027002 41017009 480 1 480 3 3 wire 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719012 51135006 58027002 41017001 600 3 1 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719040 51135006 58027002 5834...

Page 6: ...001 Blower wheel 1 46 208 240 3 1 1 52290001 208 240V Motor Double shaft 1 415 3 4wire 52290001 208 240V Motor Double shaft 277 1 52290003 277V Motor Double shaft 480 3 3wire 1 52290004 480V Motor Double shaft 480 3 4wire 52290003 277V Motor Double shaft 600 3 1 52290005 575V Motor Double shaft All 3 1 2 62441001 Blower wheel 2 66 208 240 3 1 1 52289001 208 240V Motor single shaft 1 415 3 4wire 52...

Page 7: ...re operated by and internal 24 volt source B4 Built in single stage thermostat and relays which are operated by an internal 120 volt source also includes fusing in the fan circuit and the transformer primary B5 Built in two stage thermostat and relays which are operated by and internal 24 volt source B6 Built in two stage thermostat and relays which are operated by an internal 120 volt source also...

Page 8: ...NS ISSUE DATE 06 15 01 REV DATE REV NO 00 ECO NO 1 4635 P N 00009979 SHT 08 OF 09 ΠComes factory wired as a 3 phase unit can be field converted to single phase ΠΠcomes factory wired as 480V 3 phase 4 wire unit can be field converted to 277V single phase T 46 D 08 24 1 2 B3 S C M F D P A B C D E F G H I J K L M N A Series designation T B Cabinet size 33 33 in 46 46 in 66 66 in or 79 79 in C Inlet o...

Page 9: ...1 73 14 12 25 12 9 39 14 10 5 10 6 49 98 6 43 57 6 37 70 6 21 79 10 17 45 10 35 06 8 30 68 8 16 66 10 15 35 12 15 87 12 12 28 12 12 6 12 6 59 59 4 51 90 6 44 92 6 25 95 8 20 78 10 35 06 8 30 68 8 18 56 10 15 35 12 15 87 12 12 28 12 66 6 2 2 6 3 1550 1400 31 75 8 27 90 8 24 12 8 13 95 12 11 29 14 27 58 8 24 29 8 12 25 12 14 32 12 9 82 14 9 Π3 3 9 6 46 17 6 40 40 8 34 99 8 20 20 10 16 29 12 27 58 8 ...

Page 10: ...ion trim fr trim fr trim fr trim fr trim frames are for decor ames are for decor ames are for decor ames are for decor ames are for decora a a a a tive use onl tive use onl tive use onl tive use onl tive use only they are y they are y they are y they are y they are not not not not not made for supporting the cabinet unit hea made for supporting the cabinet unit hea made for supporting the cabinet ...

Page 11: ...ns or limitations may not apply to you During the warranty period TPI Corporation will at its sole option repair or replace any defective parts or products returned freight prepaid to the TPI Corporation factory or such other locations as TPI Corporation may designate Returned products must be packaged carefully and TPI Corporation shall not be responsible for damage in transit When returning part...

Reviews: