A. INTRODUCTION

1.

Congratulations:  Thank you for purchasing TPI products. The 380 series is easy
to use and built to last. They are backed by a 3 year limited warranty. 

2.

Product Description:  The 380 series are non-contact and contact temperature
testers. They use industry standard K-type thermocouples with sub-mini con-
nector for contact measurements.

B. SAFETY CONSIDERATIONS

1.

Never point the laser beam at someone’s eyes or look directly into the beam

2.

Use caution when measuring a shiny surface so the laser does not reflect back
into your or someone else’s eyes.

3.

Do not touch the lens to any foreign object.

4.

Do not expose the unit to damp environments for extended periods of time.

* Depends upon temperature probe selected

C. TECHNICAL DATA

Distance to Spot Ratio

9 : 1  (6:1 for 381Fa)

Temperature
Range

IR Accuracy @
23°C and 0.95
emissivity

Non-contact:

380a: -4° to 572°F  (-20° to 300°C)

381Fa: -31° to 572°F (-35° to 300°C)
384a: -4° to 1832°F (-20° to 1000°C)

Contact:*

All models: -148° to 2192°F  (-100° to 1200°C)

380a & 384a:  ± 5°F (3°C) at <32°F (0°C)

± 2% of rdg or ± 3.5°F (2°C) at >32°F (0°C)

381Fa:  +/-2°F or 1.5% of rdg at 32° to 158°F (0° to 70°C)   

+/-3.5°F or 2% of rdg at <32°F (<0°C) and >158°F (70°C)

Contact Accuracy   

All models:   +(0.5% of r 3.5°F (2°C)

Emissivity

0.95

Laser Sighting

Output <1mW, Wavelength 645-660nm,

Class II Laser (Except 380a which has no laser)

°F or °C

Selectable (slide switch in handle)

Contact or Non-contact

Selectable (slide switch in handle)

Display Hold

Yes

Response Time

500 millisecond

Spectral Response

7 - 14 um

Operating Temperature

32° to 120°F   (0° to 150°C)

Battery Type

9 Volt

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for 380a

Page 1: ...ack Probes purchased separately Test the TPI Advantage Contact and non contact thermometer Maintain reading on display Laser sighting except 380a Backlit display 9 1 distance to spot ratio 6 1 for 381Fa 0 1 degree resolution 095 emissivity 3 Year Limited Warranty www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ...obe selected C TECHNICAL DATA Distance to Spot Ratio 9 1 6 1 for 381Fa Temperature Range IR Accuracy 23 C and 0 95 emissivity Non contact 380a 4 to 572 F 20 to 300 C 381Fa 31 to 572 F 35 to 300 C 384a 4 to 1832 F 20 to 1000 C Contact All models 148 to 2192 F 100 to 1200 C 380a 384a 5 F 3 C at 32 F 0 C 2 of rdg or 3 5 F 2 C at 32 F 0 C 381Fa 2 F or 1 5 of rdg at 32 to 158 F 0 to 70 C 3 5 F or 2 of ...

Page 3: ...onnected the thermometer will display open when the trigger is pulled 4 F C The selector switch is located inside the battery compartment in the handle Simply swing open the two piece handle and position the slide switch Temperature Measurement Infrared CAUTION LASER RADIATION DO NOT STARE INTO BEAM OUTPUT 1Mw WAVELENGTH 645 660nm CLASS II LASER PRODUCT 1 Set the IR K selector switch to IR Turn th...

Page 4: ...on charges to the purchaser are also covered Not Covered by Warranty Damages to the product which are the result of abuse improper use or maintenance are not covered Any other expense consequential damages incidental damages or incidental expenses including dam ages to property are not covered Transportation expenses to the company are not covered Some states do not allow the exclusion or limitati...

Reviews: