367 / 367D  

Thermometer

Instruction Manual

Summary of Contents for 367

Page 1: ...367 367D Thermometer Instruction Manual ...

Page 2: ... C TECHNICAL DATA 1 Features and Benefits 6 2 Product Applications 7 3 Specifications 8 D MEASUREMENT TECHNIQUES 1 Controls and Functions 9 2 Clock Timer Alarm 10 3 Performing Measurements 14 4 Menu Mode 22 E LOGGING PARAMETERS 367D ONLY 30 F RETRIEVING LOGGED DATA 367D 34 G OPTIONAL ACCESSORIES 34 H TROUBLESHOOTING MAINTENANCE 35 2 ...

Page 3: ... are easy to use and built to last They are backed by a 3 year limited warranty Please remember to complete and return your product warranty registration card 2 Product Description The ergonomically designed 360 series hand held ther mometers are waterproof and offer high accuracy and reliability 3 ...

Page 4: ...ted in accordance with the instruc tions and specifications given in this manual CAUTION Even though this instrument complies with the immunity standards it s accuracy can be affected by strong radio emissions not covered in the above standards Sources such as hand held radio trans ceivers radio and TV transmitters vehicle radios and cellular phones generate electromagnetic radiation that could be...

Page 5: ... your thermometer before using it to make sure it is operating properly Inspect temperature probes before using to make sure there are no breaks or shorts Double check all connections before testing NEVER Insert the probe into an electrically charged medium Touch the probe tip or shaft after it has been inserted in a hot substance 5 ...

Page 6: ...its Large LCD Easy to read measurement results High Accuracy Reliable test results Water Proof Rugged and built to last Auto Off Automatically powers off after 5 minutes of inactivity Data Logging Record and time stamp results 367D Only 6 ...

Page 7: ...thermometers Validate the temperature of incoming food product prior to accepting deliveries Measure food storage temperature Verify cooking and storage temperature Confirm hot and cold holding cabinet temperatures Measure food reheating temperatures Monitor frozen food thawing temperature 7 ...

Page 8: ... 0 1 of reading 0 4ºF 0 2ºC Resolution 100ºC 0 1ºC 100ºC 1ºC IP Rating IP 67 Units of Measure ºC ºF Selectable Operating Temperature 4ºF to 122ºF 20ºC to 50ºC 100ºC 0 1ºC 100ºC 1ºC Battery Type AA LR6 x 2 Battery Life Up to 14 000 hours Countdown Timer Select from 1 second to 24 hours Real Time Clock Yes Auto Power Off Off after 5 minutes can be disabled Over Temperature Alarm Yes Field Calibratio...

Page 9: ...The clock is displayed when the instrument is off and the timer and alarm clock are accessible Left Arrow Key is used to select parameters when the 367 is in menu mode This key is also used to activate data hold Menu Key is used to activate menu mode and is also used to cycle through various displays Right Arrow Key is used to change data start stop the timer and activate alarm mode ...

Page 10: ...yed and the coundown timer and alarm clock functions are available Press the MENU key to cycle through each of the displays Real time clock display The clock displays in a 24 hour format hh mm and can be set from the menu mode Press the MENU key to cycle to the next display ...

Page 11: ...nu mode Pressing the RIGHT ARROW key activates the timer and the arrows on the left side of the timer will begin to scroll Pressing the RIGHT ARROW key again stops and resets the timer When the countdown timer reaches 0 an alarm consisting of 3 short beeps repeating continuously will activate Press any key to turn off the alarm and reset the timer Press the MENU key to cycle to the next display ...

Page 12: ...igits will blink Press the RIGHT ARROW key to set the desired value Holding the key down will increase the value rapidly Press the LEFT ARROW key to cycle to the hour digits Press the RIGHT ARROW key to set the desired value Holding the key down will increase the value rapidly Press the LEFT ARROW key to exit no digits blinking and the alarm is set ...

Page 13: ...he alarm press the RIGHT ARROW key and an alarm bell will display next to the time To deactivate alarm mode press the RIGHT ARROW key again When the alarm clock set time is reached the alarm will begin to sound Press any key to turn off the alarm ...

Page 14: ...he input connector and use the screw collar to secure the probe to the thermometer 3 Touch or insert the probe into the item under test The temperature measured at the probe will display on the 367 Press the MENU key to set the sub display to clock mode The temperature will be dis played in the main display Please see below 4 From the temperature clock display the following functions can be perfor...

Page 15: ... Please see below To return the update rate to normal press the RIGHT ARROW key Note The update rate will automatically return to normal after 5 minutes 5 Pressing the menu key will cycle through the clock alarm clock timer and data logging 367D only functions 367D Only If you do not have a 367D please skip to page 20 6 Press the MENU key repeatedly until the sub display switches to logger display...

Page 16: ...crease each time a new measurement has been logged NOTE When logging is started all previously logged data will be overwritten 8 Pressing the LEFT ARROW key displays the current logging interval setting See below The logging interval can be changed in menu mode See appendix A 9 Pressing the LEFT ARROW key again will cycle the 367D to the log ging reserved display see below ...

Page 17: ...es LrES no reserved logging The start and stop times can be checked as shown below 11 Pressing the LEFT ARROW key displays the current logging start time See below The logging start time can be changed in menu mode See appendix A 12 Pressing the LEFT ARROW key again displays the current logging stop time See below The logging stop time can be changed in menu mode See appendix A ...

Page 18: ...low 14 Press the RIGHT ARROW key to select the location to store the cur rently displayed measurement Allow 1 second for data storage 15 Pressing the RIGHT ARROW key cycles to the next storage location There are 16 0 15 total storage locations Any existing data is overwritten when the storage location is selected ...

Page 19: ...ming Measurements 367D Only 16 Pressing the LEFT ARROW key switches the 367D to recall mode See below 17 Pressing the LEFT ARROW key selects the location to recall and dis play Allow 1 second for data retrieval ...

Page 20: ...OW key cycles through the timers The timers can be set from the menu mode Pressing the RIGHT ARROW key activates the timer and the arrows on the left side of the timer will begin to scroll Pressing the RIGHT ARROW key again stops and resets the timer When the countdown timer reaches 0 an alarm consisting of 3 short beeps repeating continuously will activate Press any key to turn off the alarm and ...

Page 21: ...ey to cycle to the hour digits Press the RIGHT ARROW key to set the desired value Holding the key down will increase the value rapidly Press the LEFT ARROW key to exit no digits blinking and the alarm is set To activate the alarm press the RIGHT ARROW key and an alarm bell will display next to the time To deactivate alarm mode press the RIGHT ARROW key again When the alarm clock set time is reache...

Page 22: ...RIGHT ARROW key to set the required time Holding down the RIGHT ARROW key will change the value rapidly 3 When changes are complete press and hold the MENU key to exit menu mode and return to normal operation or press the MENU key to cycle to the next timer 4 tr1 will change to tr2 and timer two can be set by performing the steps a b above 5 tr2 will change to tr3 and timer three can be set by per...

Page 23: ...peatedly until clock mode is displayed a Use the LEFT ARROW key to select hour minute or seconds and use the RIGHT ARROW key to set the required time Holding down the RIGHT ARROW key will change the value rapidly 3 When changes are complete press and hold the MENU key to exit menu mode and return to normal operation or press the MENU key to cycle to the function ...

Page 24: ...he menu key repeatedly until field calibration mode is dis played see display below TO USE FIELD CALIBRATION AN ICE BATH IS REQUIRED 3 Insert the temperature probe into the ice bath The measured tem perature is displayed Allow the thermometer to completely stabilize approximately 5 minutes and then press the LEFT ARROW key 4 Calibration is complete ...

Page 25: ...7 off after 5 minutes of inactivity To disable or enable this func tion perform the following steps If menu mode is active skip to step 2 1 Press the menu key repeatedly until auto power off mode is dis played see display below 2 Press the RIGHT ARROW key to activate yes or deactivate no auto power off mode ...

Page 26: ...e RIGHT ARROW key to activate Lt yes or deactivate Lt no the over temperature alarm 4 To increase the alarm point press the LEFT ARROW key until Lt uP is displayed Press the RIGHT ARROW key to increase the displayed value Holding the RIGHT ARROW key down increases the display rapidly 5 To decrease the alarm point press the LEFT ARROW key until Lt dn is displayed Press the RIGHT ARROW key to decrea...

Page 27: ... alarm mode gap is displayed see display below 3 Gap mode sets how far away from the alarm set point the tempera ture must be before the alarm sounds 4 To increase the gap point press the LEFT ARROW key until GAP uP is displayed Press the RIGHT ARROW key to increase the displayed value Holding the RIGHT ARROW key down increases the display rapidly 5 To decrease the alarm point press the LEFT ARROW...

Page 28: ...beeps and EDIT is displayed 2 Press the menu key repeatedly until unit of measurement mode is displayed see display below 3 Press the RIGHT ARROW key to switch between Celsius and Fahrenheit unit of measurement 4 After the desired unit of measure is set press the MENU key to go to the next selection or press and hold the MENU key to exit menu mode ...

Page 29: ...2 Press the menu key repeatedly until probe type selection mode is displayed see display below 3 To manually select the type of probe being used press the LEFT ARROW key to switch the main display to SEL Press the RIGHT ARROW key to select between K and T type thermocouple input 4 To return the 367 to auto select press the LEFT ARROW key until Auto is displayed 5 After the desired probe type is se...

Page 30: ...rval press the RIGHT ARROW key to set the desired value in seconds Holding the key down will increase the value rapidly Press the LEFT ARROW key and the minutes digits will blink Press the RIGHT ARROW key to set the desired value Press the LEFT ARROW key to cycle to the hour digits Press the RIGHT ARROW key to set the desired value 4 After the desired interval is set press the MENU key to go to th...

Page 31: ... start time press the RIGHT ARROW key to set the desired value in seconds Holding the key down will increase the value rapidly Press the LEFT ARROW key and the minutes digits will blink Press the RIGHT ARROW key to set the desired value Press the LEFT ARROW key to cycle to the hour digits Press the RIGHT ARROW key to set the desired value 4 After the desired start time is set press the MENU key to...

Page 32: ... stop time press the RIGHT ARROW key to set the desired value in seconds Holding the key down will increase the value rapidly Press the LEFT ARROW key and the minutes digits will blink Press the RIGHT ARROW key to set the desired value Press the LEFT ARROW key to cycle to the hour digits Press the RIGHT ARROW key to set the desired value 4 After the desired stop time is set press the MENU key to g...

Page 33: ...ivate menu mode until the 367 beeps and EDIT is displayed 2 Press the menu key repeatedly until logger reserve mode is dis played See below 3 Pressing the RIGHT ARROW key enables LrES yes or disables LrES no reserved logging 4 After the desired reserved mode is set press the MENU key to go to the next selection or press and hold the MENU key to exit menu mode ...

Page 34: ...4 Through the software all data logged can be retrieved G Optional Accessories Part Description A365 Belt clip holder A367 USB docking station belt clip cable software 367D only GT13L Bead type probe food and non food applications GT19L Bead type probe with oven clamp CT11L Surface temperature measurements FT11L Penectration Immersion measurements This is a partial listing of temperature probes av...

Page 35: ...erature probe defective Maintenance 1 Battery Replacement The 367 will display a battery symbol when the internal 1 5 Volt batteries needs replacement a Disconnect the temperature probe b Loosen the 4 battery cover screws located on the back cover c Remove the battery cover d Remove old batteries and replace with new batteries Observe the correct polarity e Reassemble the instrument in reverse ord...

Page 36: ...36 ...

Page 37: ...200ºC to 600ºC T Type Thermocouple 328ºF to 752ºF 200ºC to 400ºC Accuracy 0 1 of reading 0 4ºF 0 2ºC Resolution 100ºC 0 1ºC 100ºC 1ºC IP Rating IP 67 Units of Measure ºC ºF Selectable Operating Temperature 4ºF to 122ºF 20ºC to 50ºC Battery Type AA LR6 x 2 100ºC 0 1ºC 100ºC 1ºC Battery Life Up to 14 000 hours Countdown Timer Select from 1 second to 24 hours Real Time Clock Yes Auto Power Off Off af...