FIRE HAZARD                

EXPLOSION HAZARD 

BURN HAZARD 

 

• 

Serious injury or death 
may occur. 

 

 

• 

Read and follow all safety 
information in box below. 

OPERATING   INSTRUCTIONS

• 

Do not use outdoors or where 
flammable gases or liquids are stored.

• 

Do not use as a residential comfort 
heater. 

• 

Keep portable heater 3ft. minimum 
from all combustible materials at all 
times. 

• 

Do not modify heater in any way. 

• 

Do not provide power to heater when 
unit is near standing water. 

• 

Only use handle to move heater. 

• 

Do not touch heater housing while in 
use. 

• 

Do not allow feeder cable to contact 
combustible materials. 

• 

Always purge heat from unit after 
use. Operate at “fan only” setting for 
3 minutes.  

Fostoria FES and YES series heaters are designed
to circulate room air across its heating elements to
gradually increase room temperature. The best
performance results will be obtained when using
these heaters in smaller, confined spaces with low
ceilings. 
 
Operation of these heaters is accomplished via the
use of a multi-function thermostat (refer to
diagram below). 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
You have the option to use the fan only, or the fan
and heating elements together. Position the knob
pointer in the  “fan-only” area to circulate room
air with no heating. Move the pointer into the
“heat” area to energize the heating elements and
set the thermostat. Maximum heating is obtained
with knob turned fully clockwise. Both fan and
elements are off when the knob is turned fully
counterclockwise. 
 

Always allow the fan to operate for a minimum
of 3 minutes when you are done using the
heater to purge heat from unit. 

 

HEATER

OFF

L

N A

F

O

N

Y

LOW

HEAT

HIGH

HEAT

 

 
Note:  ALL FES/YES models are equipped with
an internal over temperature limit designed to
protect your heater if a restricted airflow
condition occurs. This limit device will
completely shutdown the heating elements if the
temperature limit is reached. The limit will
automatically reset when the unit cools. 

 

All manuals and user guides at all-guides.com

Summary of Contents for 08860010

Page 1: ...injury or death possible Read understand and follow all safety information and instructions in this manual before using or servicing this product Retain these instructions for future reference CONTEN...

Page 2: ...51228 BTUH 36 YES 3048 3A 08861210 30 480 3 36 1100 CFM 102455 BTUH 38 YES 3060 3A 08861310 30 600 3 30 1100 CFM 102455 BTUH 38 Model Part number kW Volts PH Amps Fan Output Heat Output Dim A FES 1024...

Page 3: ...installation TOP of Heater Step 2 Assemble hanger to heater per hanger assembly detail No tools are required Ceiling Mount Option Step 4 Assemble unit to mounting bracket following instructions of ch...

Page 4: ...HAZARD Serious injury or death may occur Disconnect from electrical supply before installing feeder cable to these heaters Read and follow all safety information in box to the left Feeder cable or cab...

Page 5: ...ire circuit This is an older branch circuit design that does not include a separate equipment grounding conductor green wire The configuration in fig 1 has been implemented on newer branch circuit ins...

Page 6: ...e or cable kit to heater as shown in photograph at right for the single phase models indicated 3 Phase Models Attach feeder cable or cable kit to heater as shown in the photograph at left for the foll...

Page 7: ...PHASE WIRING DIAGRAMS FES 1548 3E YES 1548 3E FES 1560 3A YES 1560 3A CABLE NOT INCLUDED CABLE NOT INCLUDED MAXIMUM OVERCURRENT PROTECTION 45 AMPS USE COPPER WIRE ONLY MAXIMUM OVERCURRENT PROTECTION 5...

Page 8: ...ES 3060 3A YES 3060 3A MAXIMUM OVERCURRENT PROTECTION 40AMPS USE COPPER WIRE ONLY WIRING continued FES YES 3 PHASE WIRING DIAGRAMS CABLE NOT INCLUDED CABLE NOT INCLUDED MAXIMUM OVERCURRENT PROTECTION...

Page 9: ...obtained when using these heaters in smaller confined spaces with low ceilings Operation of these heaters is accomplished via the use of a multi function thermostat refer to diagram below You have th...

Page 10: ...0200 2 3460200 2 3460200 2 3460200 2 21 Screw 20 x 3494156 4 3494156 4 3494156 4 3494156 4 3494156 4 3494156 4 3494156 4 22 Over temperature switch 3183900 1 3183900 1 3183900 1 3183900 1 3183900 1 41...

Page 11: ...an FES unit to a YES unit order the Fostoria kit Model WMK FES p n 04804102 Ref No Description Part No 1 Handle 8480021 2 Washer flat 3442532 3 Screw 20 x 2 3 4 2470032 4 Nut stop 20 3440132 5 Axle 84...

Page 12: ...cturer s installation instructions It further requires that he perform reasonable and necessary maintenance on the unit The company is not liable for abuse or misuse of product as may be finally deter...

Reviews: