   WIRING (continued)

TERMINAL

BLOCK

FES-1524-1A    YES-1524-1A 

FES-1524-1A    YES-1524-1A 

Attach circuit conductors at 
these lugs. Refer to label 
shown for phase 
identification 

Ground lug is located 
directly below fuse as 
shown in upper left 
corner. Securely attach 
green wire to this lug. 

Attach feeder cable or cable kit to heater as shown in
photograph at right for the single-phase models
indicated.  

 

             

3-Phase Models 

 
Attach feeder cable or cable kit to heater as shown in 
the photograph at left for the following 3-phase 
models. 
 

FES-1520-3A YES-1520-3A
FES-1524-3E YES-1524-3E 
FES-1548-3E YES-1548-3E 
FES-1560-3A YES-1560-3A
FES-3048-3A YES-3048-3A
FES-3060-3A YES-3060-3A

Ground Lug 

Securely attach green 

wire to this lug. 

Attach circuit conductors to the lugs 
on the contactor. Refer to label 
shown for phase identification. 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for 08860010

Page 1: ...injury or death possible Read understand and follow all safety information and instructions in this manual before using or servicing this product Retain these instructions for future reference CONTEN...

Page 2: ...51228 BTUH 36 YES 3048 3A 08861210 30 480 3 36 1100 CFM 102455 BTUH 38 YES 3060 3A 08861310 30 600 3 30 1100 CFM 102455 BTUH 38 Model Part number kW Volts PH Amps Fan Output Heat Output Dim A FES 1024...

Page 3: ...installation TOP of Heater Step 2 Assemble hanger to heater per hanger assembly detail No tools are required Ceiling Mount Option Step 4 Assemble unit to mounting bracket following instructions of ch...

Page 4: ...HAZARD Serious injury or death may occur Disconnect from electrical supply before installing feeder cable to these heaters Read and follow all safety information in box to the left Feeder cable or cab...

Page 5: ...ire circuit This is an older branch circuit design that does not include a separate equipment grounding conductor green wire The configuration in fig 1 has been implemented on newer branch circuit ins...

Page 6: ...e or cable kit to heater as shown in photograph at right for the single phase models indicated 3 Phase Models Attach feeder cable or cable kit to heater as shown in the photograph at left for the foll...

Page 7: ...PHASE WIRING DIAGRAMS FES 1548 3E YES 1548 3E FES 1560 3A YES 1560 3A CABLE NOT INCLUDED CABLE NOT INCLUDED MAXIMUM OVERCURRENT PROTECTION 45 AMPS USE COPPER WIRE ONLY MAXIMUM OVERCURRENT PROTECTION 5...

Page 8: ...ES 3060 3A YES 3060 3A MAXIMUM OVERCURRENT PROTECTION 40AMPS USE COPPER WIRE ONLY WIRING continued FES YES 3 PHASE WIRING DIAGRAMS CABLE NOT INCLUDED CABLE NOT INCLUDED MAXIMUM OVERCURRENT PROTECTION...

Page 9: ...obtained when using these heaters in smaller confined spaces with low ceilings Operation of these heaters is accomplished via the use of a multi function thermostat refer to diagram below You have th...

Page 10: ...0200 2 3460200 2 3460200 2 3460200 2 21 Screw 20 x 3494156 4 3494156 4 3494156 4 3494156 4 3494156 4 3494156 4 3494156 4 22 Over temperature switch 3183900 1 3183900 1 3183900 1 3183900 1 3183900 1 41...

Page 11: ...an FES unit to a YES unit order the Fostoria kit Model WMK FES p n 04804102 Ref No Description Part No 1 Handle 8480021 2 Washer flat 3442532 3 Screw 20 x 2 3 4 2470032 4 Nut stop 20 3440132 5 Axle 84...

Page 12: ...cturer s installation instructions It further requires that he perform reasonable and necessary maintenance on the unit The company is not liable for abuse or misuse of product as may be finally deter...