5.
7
Foot pedal
Winding machine may be equipped with the following types of foot pedal:
Double foot pedal controls START, BRAKE RELEASE
- left pedal releases the spindle brake
- right pedal works in parallel with the START-button
Double foot pedal controls SPEED, BRAKE RELEASE
- left pedal releases the spindle brake
- right foot pedal controls spindle speed depending how hard the pedal is pressed.
Maximum speed, acceleration and deceleration ramp can be set up by PEDAL button.
Speed set up in this way is applicable only for the current programme. It is independent of the
speed programmed in a specific programme step. Eg.: maximum speed set up by START
pedal may be differ to maximum speed set up by START button.
There is a time delay 0,5 sec between repeated presses for safety work to prevent
unintended start of the next step.
14 / ERN T / V 1.3
Acceleration and deceleration ramp values are always taken from window PEDAL SETUP.
CODE
1
2
3
4
5
6
7
8
ACC.TIME
DEC.TIME
1,0
1,6
2,4
3,0
4,0
5,0
6,0
8,0
0,5
0,8
1,2
1,5
2,0
2,5
3,0
4,0
( sec )
( sec )
Accel. and dec. ramp for pedal
2
1
3
Summary of Contents for ERN 100T
Page 8: ...5 ERN T V 1 3 UPS POWER MAN I 0 TOTAL STOP BRAKE 8 9 10 11 12...
Page 36: ...Type of cycle 33 ERN T V 1 3 1 2 7 2 5 Delay Time of delay PROGRAM PROGRAM PROGRAM 2 1 3...
Page 50: ...48 ERN T V 1 3 Delay 1 2...
Page 53: ...51 ERN T V 1 3 Copy step 1 2 Pressing of button COPY STEP ends copying...
Page 54: ...52 ERN T V 1 3 Delete step 1 2...
Page 56: ...54 ERN T V 1 3...