background image

III

Audience  

This Installation Guide is for:

Network Engineer

Network Administrator

Conventions  

Due to the similarity in the structure of the L2 Managed Switch series, in this 

Installation Guide we take TL-SG5428 as an example to illustrate Chapter 2 Installation, 

Chapter 3 Lightning Protection and Chapter 4 Connection.

This guide uses the specific formats to highlight special messages. The following table 

lists the notice icons that are used throughout this guide.

Remind to be careful. A caution indicates a potential which may 
result in device damage.
Remind to take notice. The note contains the helpful 
information for a better use of the product.

Audience

Summary of Contents for JetStream TL-SG5412F

Page 1: ...Installation Guide L2 Managed Switch TL SG5428 TL SG5412F Business Networking Solution...

Page 2: ...nment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication...

Page 3: ...ing installation This Installation Guide is structured as follows Chapter 1 Introduction This chapter describes the External Components of the Switch Chapter 2 Installation This chapter illustrates ho...

Page 4: ...illustrate Chapter 2 Installation Chapter 3 Lightning Protection and Chapter 4 Connection This guide uses the specific formats to highlight special messages The following table lists the notice icons...

Page 5: ...Protection 08 3 1 Cabling Reasonably 08 3 2 Connect to Ground 10 3 3 Equipotential Bonding 11 3 4 Use Lightning Arrester 12 Chapter 4 Connection 13 4 1 Ethernet Port 13 4 2 SFP Port 13 4 3 Console Por...

Page 6: ...nd multiple powerful functions with high security The EIA standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks ACL 802 1x and Dynamic...

Page 7: ...port and data is being transmitted or received Yellow On A 10 100Mbps device is linked to the corresponding port and there is no activity Flashing A 10 100Mbps device is linked to the corresponding p...

Page 8: ...ed to connect with the serial port of a computer or terminal for monitoring and configuring the Switch Rear Panel Due to the similarity of TL SG5428 and TL SG5412F in the rear panel here TL SG5428 is...

Page 9: ...ded with the switch Make sure that the supply voltage matches the specifications indicated on the rear panel of the switch Ensure the vent hole is well ventilated and unblocked Do not open or remove t...

Page 10: ...tatic electricity on the operation of the Switch please attach much importance to the following items Dust the device regularly and keep the indoor air clean Keep the device well grounded and ensure s...

Page 11: ...ch is flat and stable and sturdy enough to support the weight of 5 5kg at least The rack or workbench has a good ventilation system The equipment room is well ventilated The rack is well grounded Keep...

Page 12: ...ch side of the device with supplied screws as illustrated in the following figure TL SG54 28 Rack mounting Bracket Screw Figure 2 2 Bracket Installation 3 After the brackets are attached to the device...

Page 13: ...or shielding Before connecting the cable to the device install a signal lightning arrester on the corresponding port When an aerial cable is set up the cable should be through a metal pipe 15m long at...

Page 14: ...you can add a steel tube or metal raceway for shielding Requirements for the distance between Ethernet cable and high power electric devices are in following tables Cable Pave Way Min Parallel Length...

Page 15: ...cific operation environment Connecting to the Grounding Bar If the device is installed in the Equipment Room where a grounding bar is available you are recommended to connect the device to the Groundi...

Page 16: ...the ground or overground metal so as to create an earthed equipotential zone When lightning occurs the high voltage produced by lightning current in all systems will meanwhile exist in their ground ca...

Page 17: ...signal lightning arrester please observe the following rules The port rate of the signal lightning arrester should match the rate of the desired port on the device If it is not matched this signal li...

Page 18: ...nnection of SFP port to a SFP module TL SG542 8 SFP Slot Figure 4 2 Inserting the SFP Module Note A Combo port refers to two Ethernet interfaces in a device panel normally one is an SFP slot and the o...

Page 19: ...gle mode fiber Multi mode fibers generally have a larger core diameter and are used for short distance communication links and for applications where high power must be transmitted Single mode fibers...

Page 20: ...on the right of the front panel Please keep the device power off when plugging the console cable Do not connect the console port with other ports by RJ45 cable 4 4 Verify Installation After completin...

Page 21: ...powered on it begins the Power On Self Test A series of tests run automatically to ensure the device functions properly During this time its LED indicators will respond in the following order The PWR...

Page 22: ...the switch The IP address is 192 168 0 x x is any number from 2 to 254 Subnet Mask is 255 255 255 0 For the detailed instructions as to how to do this please refer to Appendix B in the User Guide on...

Page 23: ...on the PC 3 Configure the terminal emulation program or the terminal to use the following settings Baud rate 38400 bps Data bits 8 Parity none Stop bits 1 Flow control none 4 The DOS prompt TP LINK w...

Page 24: ...the command prompt shown as Figure 5 6 and press the Enter button Figure 5 6 Connecting to the switch 4 Type the User name and Password the factory default value for both of them is admin and press t...

Page 25: ...s the requirement of the input voltage of the switch Q3 What could I do if I could not access the web based configuration page You are recommended to check the following items 1 Check every port LED o...

Page 26: ...10Base T UTP STP of Cat 3 or above 100m 100Base TX 2 pair UTP STP of Cat 5 or above 100m 1000Base T 4 pair UTP STP of Cat 5e or above 100m 1000Base X MMF or SMF SFP Module Optional LEDs PWR SYS 1000Mb...

Page 27: ......

Page 28: ...Website http www tp link com Tel 86 755 26504400 E mail support tp link com 7106505361 REV2 0 3...