background image

ENGLISH

2

3.  OPERATION

UNIT SET UP (Fig. F)

  •  Place the unit in an upright position on a stable, flat surface.
  •  Ensure that the unit is a safe distance away from a wall or fur

-

niture (Fig. F1).

  •  Keep clothes at a safe distance of 40 cm from air outlet of the 

unit to prevent water dripping into the unit.

CAUTION

  •  Keep suitable space as above. (F2)
  •  DO NOT insert small objects into the unit or this will damage it 

and cause a hazard. (F3)

  •  DO NOT remove water tank when running or water may leak. 

(F4)

  • 

Ensure that the water tank is fitted correctly, if the tank is full or 
is not in place, the “Full tank / Check” lights and the machine 
stops. (F4)

HUMIDISTAT
OPERATING STEPS:

1.  By  turning  the  knob  (C1)  clockwise,  unit  starts  the  operation 

and the dehumidification is started.

2. 

As the knob turned closer to the indication of 'Cont.', the set-
ting room humidity become lower.

3. 

When the knob is turned to the rightmost position, the opera-
tion mode become continuous operation.

4. 

The  knob  (C1)  is  recommended  to  be  set  in  the  range  of  'A' 
(Fig. J).

  CAUTION

In case that the knob is set in the range of 'B' (Fig. J), after the 
automatic  operation  is  stopped,  it  may  take  time  to  start  the 
operation again depends on the room environment.

5.  STOP OPERATION

 

Turn the knob (C1) counterclockwise to switch off and the run-
ning lamp (C3) will be off.

POWER SELECTION SWITCH
OPERATING STEPS:
1. 

Turn  the  knob  (C2)  clockwise  to  select  HIGH  MODE  (high  
heating power and high fan speed). Select this mode for short-
turm rapid dehumidification

2. 

Turn  the  knob  (C2)  counterclockwise  to  select  LOW  MODE 
(low heating power and low fan speed). Use this mode for nor-
mal daily use, energy saving and quiet operation.

IONISER OPERATION:
1.

  When the unit is on, the IONISER and the Ionizer lamp (C3) will 

be on.

2.

  When the unit is off, the IONISER and the Ionizer lamp (C3) will 

be off.

HORIZONTAL ADJUSTABLE LOUVER  (Fig. G)

The air outlet can be adjusted forward or upward.

WIDE / SPOT ADJUSTABLE LOUVER (Fig. H)

Wide blowing (H1) 

  Adjust the blades outwards for an expanded 

airflow.

Spot blowing (H2) 

  Adjust the blades inwards for a spot airflow.

CONTINUOUS DRAINAGE MODE (Fig. E)

For  continuous  drainage,  use  a  hose  with  an  inner  diameter  of 
12mm and outer diameter of 14mm~16mm.
1.  Remove the water tank.
2.  Use  a  screwdriver  to  remove  the  knockout  at  the  back.  (E1) 

Pushing down and hold the stopper (E4) for drainage pipe by 
finger  (Fig.  E2).  Attach  the  hose  to  the  drainage  pipe  (E5) 
through the hole (Fig. E3).

3.  Remove  the  tank  cover  and  restore  the  water  tank  into  the 

unit.

 

If  the  tank  is  not  restored  in  the  unit,  full  tank  lamp  will  light 
and cannot start operation.

4.  The  tubing  should  be  lead  to  the  drain  with  no  sharp  bends. 

(E6, E7, E8)

NOTE:
1.  The water tank must be in the correct position before tubing.
2.  Remove the tubing before pulling out the water tank.
3.  Remove the hose from the continuous drainage hole. Be sure 

to put the tank cover on the water tank and restart operation.

4.  EMPTY THE WATER TANK (Fig. D)

1.  When the water tank is full, the Water full indicator lamp (C4) 

will light and unit stops in a few minutes.
NOTE: DO NOT move the unit or remove the water tank, if the 

unit  is  still  operating,  as  water  may  leak,  damage  the 
unit or cause an electric shock.

2.  By gripping the bottom of the bucket, remove the water tank 

(D1) and lift carefully with handle (D2)

3.  Remove the cover of water tank first (D3), then pour the water 

away (D4). Clean the water tank and restore the cover and the 
water tank (D5) to the correct position.

 

NOTE:

  •  Clean the water tank with clean water if needed. DO NOT 

use solvent, abrasive or hot water.

  •  DO  NOT  remove  or  damage  the  float  in  the  tank,  or  the 

unit cannot work correctly.

  •  The water tank cover must be well fitted in position.
  •  The water full indicator lamp lights if the water tank is not 

well in the position.

CLEANING

CLEANING AIR INTAKE GRILLE (Fig. I)

If the filter is covered with dust, the airflow and the performance of 
the unit will be affected. It is recommended to check and clean the 
air filter every 2 weeks.
1.  Turn off the unit and remove the filter from the unit. (I1)
2.  Clean the nano-silver filter with a vacuum cleaner or wash with 

water  (under  40°C).  (I2)  If  you  wash  with  water,  dry  it  com-
pletely at shaded area.

3.  Replace the filter in position.

CLEANING SURFACE

1.  Turn off the unit, wait for the fan to stop and unplug from the 

power socket.

2.  Clean the surface with a soft damp cloth.
3.  Dry thoroughly with a towel after cleaning.
4.  In order to avoid damage, do not wash the unit with water, or 

let water drip into the air inlet or outlet.

CAUTION

  •  NEVER use gasoline, solvents, chemical products or polish as 

they could damage the surface.

5.  LONG-TERM STORAGE

At the end of each season, or when you do not plan to use your 
unit  for  an  extended  period  of  time,  the  following  procedures  are 
recommended.
1.  Turn off the unit, wait for it to stop and unplug from the power 

socket.

2.  Clean and dry the water tank. Leave the unit to drain for ap-

proximately one day.

3.  Clean the filter and the unit. Cover the unit to prevent it from 

gathering dust. Store upright in a cool dry place. DO NOT ex-
pose to direct sunlight.

CAUTION

  •  ALWAYS store the unit in the vertical position.
  •  DO NOT put heavy objects on top of the unit.

Summary of Contents for TD-ZM80

Page 1: ...PTIE LUCHTONTVOCHTIGER DEUMIDIFICATORE CON COMPRESSORE AFFUGTER AF T RREMIDDELTYPE OPERATING MANUAL ENGLISH P 1 MANUAL D UTILISATION FRAN AIS P 5 BEDIENUNGSANLEITUNG DEUTSCH P 9 GEBRUIKSAANWIJZING NED...

Page 2: ...A B E D C3 C4 C1 C2 D1 D2 D3 D4 D5 B1 B2 B3 B4 A1 A2 A3 A4 A5 A6 A9 A7 A8 E2 E3 E4 E5 E1 E6 E7 E8 C...

Page 3: ...more than 50cm more than 40cm When louver closed more than 20cm When louver up Top more than 60cm more than 20cm more than 20cm G J I F F3 F2 F4 H1 H2 I1 I2 F1 H G1 B A...

Page 4: ...cal shocks or other injury to person or property When using electrical appliances basic safety precautions should always be followed DO NOT operate the unit with a damaged cord or plug after it malfun...

Page 5: ...the tank is not restored in the unit full tank lamp will light and cannot start operation 4 The tubing should be lead to the drain with no sharp bends E6 E7 E8 NOTE 1 The water tank must be in the co...

Page 6: ...s Dehumidifier is blowing out warm air The dried air is past over a heating ele ment before it is blown into the room as part of the dehu midification pro cess This is normal a dehumidifier is not an...

Page 7: ...y in basis to your nearest au thorized dealer or distributor of TOYOTOMI WHAT YOU MUST DO FOR WARRANTY SERVICE You must return the defective Product or part to any authorized dealer or distributor of...

Page 8: ...NEW 10 15 TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan www toyotomi jp Printed in China...