![Toyotomi MUL12- FWCA Service Manual Download Page 9](http://html1.mh-extra.com/html/toyotomi/mul12-fwca/mul12-fwca_service-manual_1143430009.webp)
9
PRODUCT
Notes:
a.
The rated cooling capacity data is measured under the following work condition: Indoor Temperature is
27
ć
DB, 1 9
ć
WB. Outdoor Temperature is 35
ć
DB.The rated heating capacity data is measured under the following
work condition: Indoor Temperature is 20
ć
DB. Outdoor Temperature is 7
ć
DB, 6
ć
WB.
b.
The data will change with the change of products. Refer to those parameters listed on nameplate.
c.
Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
4.3 Working Temperature Range
Indoor side state
Outdoor side stae
Dry bulb temp.
ć
Wet bulb temp.
ć
Dry bulb temp.
ć
Wet bulb temp.
ć
Rated Cooling
27
19
35
24
Max. cooling
32
23
48
26
Min. cooling
21
15
18
—
Rated Heating
20
15
7
6
Max. heating
27
—
24
18
Min. heating
20
15
ˉ
15
ˉ
16
Notes
˖
a. The heating/cooling capacity and noise listed below are all measured before the shipment.
b. All parameters listed below are measured under the standard working conditions. If there is any change, the
parameters marked on the nameplate always prevail.
c. The heating capacity of the indoor unit just involves that of the heat pump but apart from that of the auxiliary
electric heater.
Summary of Contents for MUL12- FWCA
Page 1: ...Service Manual MODEL MUL FWCA Series...
Page 4: ...1 PRODUCT...
Page 11: ...11 CONTROL CONTROL...
Page 30: ...54 MAINTENANCE...
Page 41: ...66 MAINTENANCE 3 2 Indoor unit 3 2 2 Cassette type MUL12 FWCA MUL18 FWCA MUL24FWCA...
Page 44: ...91 MAINTENANCE 5 2 2 Cassette type MUL12 FWCA...
Page 46: ...93 MAINTENANCE MUL18 FWCA...
Page 48: ...95 MAINTENANCE MUL24 FWCA...