background image

Part Code

         FS 1060Ao

1

Panel Grille

22414102

2

2

Cabinet

01435436

1

3

Rear Grill

01475432

1

4

Top Cover

01255472

1

5

Rear Side Plate Sub-Assy

01303712

1

6

Handle

26235253

2

7

Valve Support Sub-Assy

01715001

1

8

Chassis Sub-assy

01205472

1

9

Front Side Plate

01305431

1

10

Sensor supprt

24211341

1

11

Axial-flow Fan

10335253

2

12

Condenser Assy

01105341

1

13

Motor Support Sub-Assy

01705471

1

14

Fan Motor

15015451

2

15

Mid-clapboard sub-assy

01235473

1

16

Inhalation Tube Sub-Assy

03639066

1

17

4-way Valve Assy

03025268

1

18

4-way Valve Accessary

430004002

1

19

Compressor and fittings

00129052

1

20

Assistant Capillary Sub-Assy

03005283

1

21

Cut-off Valve 3/4(R410A)

07130212

1

22

Electric heater(compressor)

76515404

1

23

Condenser support sub-assy

01894148

1

24

Temperature Sensor

39000129

1

25

Air-out Temp. Sensor

39000163

1

26

Outdoor Tube Sensor

39000127

1

27

Electric Box Assy

014054709

1

28

AC Contactor

44010236

1

29

Over Current Protector

46020103

1

30

Transformer

43110242

1

31

Relay

44020332

1

32

Terminal Board

42010258

2

33

Capacitor CBB61

33010013

2

34

Phase Reverse Protector

46020052

1

35

Relay

44020369

1

36

Terminal Board

42011103

2

37

Drainage Connecter

06123401

1

38

Drainage Plug

06813401

2

39

Pressure Protect Switch

460200061

1

40

Low pressure switch

46020007

1

No

Description

Qty

Parts list of outdoor unit

Summary of Contents for FS1060A

Page 1: ...Service Manual MODEL FS1060A...

Page 2: ...1 Introduction and Features Model Remarks FS 1060A...

Page 3: ...essure Level dB A H M L Sound Power Level dB A H M L Dimension H W D mm Dimension of Package L W H mm Net Weight Gross Weight kg 2000 720 515 60 85 7 3 1 4 914 4X471X42 2 SM016 540 1750 380 4W PCB 5 0...

Page 4: ...Discharge Side MPa Permissible Excessive Operating Pressure for the Suction Side MPa Sound Pressure Level dB A H M L Fan Diameter mm Defrosting Method Climate Type Isolation Fan Motor RLA A Fan Motor...

Page 5: ...r outlet display screen panel air intake panel air intake air discharge remote controller timer swing fan speed mode ON OFF temperature air intake display screen drain pipe air discharge connecting pi...

Page 6: ...4 Outline and Installation Dimension Indoor unit s outline and installation size unit rear front Pipe side should be at least 30cm Pipe side should be at least 30cm...

Page 7: ...Outdoor unit s outline and installation size unit more than more than 600 more than 600 more than 600 bolt nut...

Page 8: ...5 If above electric circuit diagram has been changed please refer to it on the body...

Page 9: ...case the compressor and outdoor fan will started and the indoor fan will run at low speed When Tpreset 2 T amb Tpreset 2 the compressor indoor fan and outdoor fan will run 6 minutes and stop 4 minute...

Page 10: ...d Mid Speed High Speed The temperature can be set within a range from 16 to 30 The initial value is 25 AUTO Mode Under this mode the system will automatically select its running mode cooling dry heati...

Page 11: ...After the power is failed if it s re energized the unit will automatically start to run by the memory of last time Button MODE button Press MODE key to select and display the run mode as below Press F...

Page 12: ...w pressure Protection meanwhile the indicator will blink and E1 will be displayed the complete unit will be stopped and the indicator will flicker In 3 minutes the unit will restore running automatica...

Page 13: ...nd 6 tapping screws on condenser side plate and then remove the grill net 2 Disassemble the top cover plate Unscrew the tapping screws around top cover plate and pull it upward then remove the top cov...

Page 14: ...sassemble panel Unscrew 2 screws used for fixing the panel pull the panel downward and pull out the signal wire then remove the panel 6 Disassemble air damper and the mounted plate of water tray Unscr...

Page 15: ...s used for connecting air outlet and top cover and the 2 screws used for connecting left plate and right plate 8 Disassemble chassis Unscrew the screws around the chassis and pull it outward then disa...

Page 16: ...r Unscrew the screws around the top cover and then remove the top cover 11 Disassemble air damper and the mounted plate of water tray Press the diversion circle by hand to rotate it in clockwise direc...

Page 17: ...ew the 2 screws on the mounted plate of evaporator and then remove it 13 Disassemble the left side and right side plates Unscrew the screws used for connecting the left and right side plates and rear...

Page 18: ...Disassemble evaporator Unscrew the 2 screws used for fixing evaporator and then remove evaporator Unscrew the 4 screws used for fixing the electric heating and then remove it 16 Disassemble motor Unsc...

Page 19: ...case and then remove it 5 Disassemble electric box Unscrew the screws around the electric box and then remove the electric box assy 6 Disassemble right side plate Unscrew the screws around the right...

Page 20: ...or support lift it upward and then remove the motor support 9 Disassemble four way valve Unscrew the fixing nut of the four way valve coil and remove the coil Wrap the four way valve with wet cotton a...

Page 21: ...the remove the valve 11 Disassemble capillary Unsolder the weld spot used for connecting capillary and other pipes and then remove the capillary 12 Disassemble compressor Unscrew 4 foot screws of com...

Page 22: ...8 Assembly Drawing and Parts List Assembly drawing for indoor unit parts...

Page 23: ...Motor 15214215 1 18 Air Louver 10514452 6 19 Filter Sub Assy 11144471 1 20 Air Intake panel Assy 200044711 1 21 Electric Box Cover Sub Assy 01404403 1 22 Fuse 46010013 1 23 Relay 44020331 3 24 Relay 4...

Page 24: ...Assembly drawing for outdoor unit...

Page 25: ...pressor and fittings 00129052 1 20 Assistant Capillary Sub Assy 03005283 1 21 Cut off Valve 3 4 R410A 07130212 1 22 Electric heater compressor 76515404 1 23 Condenser support sub assy 01894148 1 24 Te...

Page 26: ...heating or cooling Flow malfunction of refrigerant Malfunction of compressor Refrigerant volume is insufficient Malfunction of four way valve Replace four way valve Fill with refrigerant Replace comp...

Page 27: ...s broken Wrong wire connection Connect the wire correctly according to the electric circuit diagram Indoor fan s motor is burnt our or its wire is broken Repair it or replace fan s motor Fan s capacit...

Page 28: ...tes The pipes for outdoor unit are in collision with each other Separate the collision pipes Abnormal vibration for the compressor Adjust the compressor s support mat and fasten the loose bolt There a...

Reviews: