Controller
Electrical Control System
3.2 Wired Remote Controller
3.2.1 KJR-10B
Name and functions of buttons on the wire controller
1
mode selection button:
It is used to select mode, push the button one time, then the operation modes will change
In turn as follows:
AUTO
COOL
DRY
HEAT
FAN
Remark: no heating mode if wire controller is set as the cool only.
2
Timer on button:
Push the button to set TIMER ON, each time you push the button the time moves forward by o.5 hours.
When the set time is over 10 hours, each time you push the button the time moves forward by 1 hour. If
want to cancel the TIMER ON, then adjust the time of TIMER ON as 0.0
3
Timer off button:
Push the button to set TIMER OFF, each time you push the button the time moves forward by o.5 hours.
When the set time is over 10 hours, each time you push the button the time moves forward by 1 hour. If
want to cancel the TIMER OFF, then adjust the time of TIMER OFF as 0.0
4 CLOCK
button:
Normally display the clock set currently (display 12:00 for the first electrifying or resetting). When push
the button for 4 seconds, the hour part on the clock display flashes every 0.5 seconds, then push button
and to adjust hour; push the button CLOCK again, the minute part flashes every 0.5 seconds, then push
and button to adjust minute. When set clock or alter clock setting, must push the confirm button to
complete the setting
5
6. NAME AND FUNCTIONS OF BUTTONS ON WIRE
CONTROLLER
ON / OFF button
ķ
ĸ
Ĺ
ĺ
Ļ
ļ
Adjust button ▲
Adjust button ▼
I
TIMER ON
TIMER OFF
TEMP
REPLACE LOCK
COOL
HEATING
MODE
FAN SPEED
CLOCK
CONFIRM
ECONOMICAL
SWING
Economical button
Swing button
COOL ONLY/COOL and
Heating selection button
Lock button
Timer on button
Timer off button
Clock button
confirm button
replace nutton
Mode selection button
Fan speed selection
Reset button
RESET
OK
Ok button
Summary of Contents for DCT 100HSPi
Page 1: ...Service Manual MODEL DCT 100HSPi o DCT 140HSPi o DCT 170HSPi o ...
Page 6: ...Indoor units Indoor units Part 2 Indoor units High Static Pressure Type ...
Page 9: ...Dimensions Indoor units 2 Dimensions 2 2 DCT 100HSPi 2 3 DCT 140HSPi DCT 170HSPi ...
Page 12: ...Wiring diagrams Indoor units 5 4 DCT 100HSPi 2 3 DCT 140HSPi DCT 170HSPi ...
Page 16: ...Static pressure Indoor units 10 Static pressure DCT 100HSPi DCT 140HSPi DCT 170HSPi ...
Page 19: ...Dimensions Outdoor units 1 3 DCT 100HSPo 1 4 DCT 140HSPo DCT 170HSPo ...
Page 21: ...Wiring diagrams Outdoor units 3 4 DCT 100HSPi 3 5 DCT 140HSPi DCT 170HSPi ...
Page 33: ...Installation Installation Part 4 Installation QVWDOODWLRQ ...
Page 41: ...Control Control Part 5 Control RQWURO ...
Page 45: ...Control Control ...