![Toyotomi CTG-228BRM User Manual Download Page 46](http://html.mh-extra.com/html/toyotomi/ctg-228brm/ctg-228brm_user-manual_1143305046.webp)
46
GB
• Stick the label on the system after
fi
lling is
fi
nished (or haven’t
fi
nished).
• Don’t
over
fi
lling.
•
After
fi
lling is
fi
nished, please do the leakage detection before test running;
another time of leak detection should be done when it’s removed.
Safety instructions for transportation and storage
•
Please use the
fl
ammable gas detector to check before unload and open
the container.
• No
fi
re source and smoking.
• According to the local rules and laws.
Installation of outdoor unit
Step 1: Fix the support of outdoor unit
(select it according to the actual installation situation)
1.
Select installation location according to the
house structure.
2.
Fix the support of outdoor unit on the
selected location with expansion screws.
NOTE
• Take
suf
fi
cient protective measures when installing the outdoor unit.
• Make sure the support can withstand at least four times of the unit weight.
•
The outdoor unit should be installed at least 3cm above the
fl
oor in order
to install drain joint.
•
For the unit with cooling capacity of 2300W ~ 5000W, 6 expansion screws
are needed, for the unit with cooling capacity of 6000W~8000W, 8 expansion
screws are needed, for the unit with cooling capacity of 10000W~16000W,
10 expansion screws are needed.
at least 3cm above the
fl
oor