Troubleshooting
50
TOX_Manual_FinePress_PFS-PFL-PFW_en
9.2
Detecting faults
If the press is equipped with a control system, the faults or warnings on the
central control unit are displayed and described.
Fault
Cause
Measures
The ram does not ex-
tend.
There is a mechanical fault on the
guide.
Contact authorized service personnel.
Power stroke does not
initiate
Insufficient air pressure
Check the air pressure.
Pneumatic line on cylinder is de-
fective
Contact authorized service personnel.
Mechanical defect on pneumatic
cylinder
Contact authorized service personnel.
Fault on control system
Contact authorized service personnel.
The nominal force not
reached.
There is a mechanical fault on the
guide.
Contact authorized service personnel.
The press head is not adequately
fastened.
Tighten the fastening screws evenly. Observe
the tightening torques, see: