Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
85
Field
Meaning
1
Total counter value
Total number of parts (OK and NOK) that
were produced with this tool.
2
Reset
Reset of counter Total counter reading
3
Main menu total
The counter reading is displayed in the
main menu when the checkbox is acti-
vated.
4
Message at total
The number of the total parts reached at
which a stored yellow message is issued
on the display. Value 0 deactivates the
function.
5
Switch-off at total
The number of the total parts reached at
which the working process is ended and
a stored red message is issued on the
display.
6
Accept
The settings are applied.
The window will close.
Tool counter - Switch-off at total
A limit value can be entered in the input field
Switch-off at total
. Once the
counter value reaches the value, the working process shuts down and a
corresponding message is issued.
The value
0
deactivates the corresponding option. The system is not shut
down and no message is issued.
ü
The user is logged in with a suitable user level. The necessary write
permissions are available.
ü
Menu ''Lot size\Tool counter'' is open
1.
Tap on the
Switch-off at total
input field.
w
The numerical keyboard opens.
2.
Enter the limit value and confirm with
↲
.
Value
0
deactivates the function.
Reset ''Switch-off at total'' counter
1.
When the limit value in input field ''Switch-off at total'' has been
reached:
2.
Reset the counter by tapping on the
Reset
button.
3.
Start process again.
Summary of Contents for CEP400T
Page 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Page 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 117: ......
Page 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Page 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...