Technical data
TOX_Manual_Process-monitoring-unit_CEP400T_en
47
1
After it has been switched on, the device signals that it is ready for measure-
ment by setting the >Ready> signal.
2
When closing the press the signal <Start measurement> is set.
3
The OK/NOK signal is reset. The <Measurement in progress> signal is set.
4
When the conditions for triggering the return stroke have been met and the
minimum time has been reached (must be integrated in the overriding con-
trol), the 'Start' signal is reset. The measurement is evaluated when the <S-
tart> signal is reset.
5
The <OK> or <NOK> signal is set and the <Measurement in progress> sig-
nal is reset. The OK or NOK signal remains set until the next start. When the
function 'Number of pieces / Warning limit' is active, the OK signal that was
not set must be used for the NOK evaluation. See the sequence at active
warning limit / number of pieces.
4.14.2
Measuring mode
This description applies to versions with active warning limit monitoring and
number of pieces monitoring.
Signal name
Type:
Input "I" / Output "O"
Designation
A0
o
Part is OK (OK) K1
A1
o
Part is not OK (NOK) K1
A6
o
Measure K1 in progress
A5
o
Ready for measurement (ready)
E6
I
Start measurement K1
Tab. 15
Basic device signals
1 2 3
4 5
2 3
4
5
2 3
4 5
1
0
1
0
1
0
1
0
1
0
Cycle IO
Ciclo
Cycle IO/warning limit or
quantity during life reached
IO (O1)
Quantity during life/
warning limit (O2)
Meas. running (O7)
Ready (O6)
Start (I7)
Fig. 8
Sequence with warning limit/number of pieces monitoring.
1
After it has been switched on, the device signals that it is ready for measure-
ment by setting the >Ready> signal.
2
When closing the press the signal <Start measurement> is set.
3
The OK/NOK signal is reset. The <Measurement in progress> signal is set.
Summary of Contents for CEP400T
Page 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Page 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 117: ......
Page 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Page 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...