Software
74
TOX_Manual_Process-monitoring-unit_CEP400T_en
Setting the force sensor filter
By setting a filter value the higher frequency deviations of the measuring
signal can be filtered out.
ü
The user is logged in with a suitable user level. The necessary write
permissions are available.
ü
The ''Configuration -> Force sensor configuration '' menu is opened.
è
Tap on the
Filter
input field.
w
Each tap changes the value between
OFF
,
5
,
10
,
20
,
50
,
100
,
200
,
500
,
1000
.
Force sensor calibration
In menu ''Enter Configuration -> Configuration of force sensor\Nominal
force'' the measured electrical signal is converted to the corresponding
physical unit with the values of nominal force and offset. If the values for
nominal force and offset are not known, they can be determined via the cal-
ibration. For this a 2-point calibration is carried out. The first point here can
be the opened press with 0 kN force applied for example. The second
point, for example, can be the closed press when 2 kN force is applied. The
applied forces must be known for carrying out the calibration, for example,
which can be read on a reference sensor.
è
Open the ''Enter Configuration -> Force sensor configuration\Nominal
force'' by tapping the button
in ''Configuration\Configuration of
force sensor\''.
Summary of Contents for CEP400T
Page 2: ...2 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 12: ...Important information 12 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 16: ...Safety 16 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 22: ...About this product 22 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 52: ...Transport and storage 52 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 54: ...Commissioning 54 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 56: ...Operation 56 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 98: ...Software 98 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 101: ...Troubleshooting TOX_Manual_Process monitoring unit_CEP400T_en 101 9 1 3 Error messages ...
Page 108: ...Maintenance 108 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 110: ...Maintenance table 110 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 112: ...Repairs 112 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 114: ...Disassembly and Disposal 114 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 116: ...Appendices 116 TOX_Manual_Process monitoring unit_CEP400T_en ...
Page 117: ......
Page 118: ...Appendices 118 TOX_Manual_Process monitoring unit_CEP400T_en 13 2 UL certificate ...
Page 126: ...Index 126 TOX_Manual_Process monitoring unit_CEP400T_en ...