YW1838
9
Next Free User ID
Key Sequence
[#]
[Master Code] ● [10] ●●
If a next free user ID is recognized, the following sequence will occur:
•
At the start of the Next Free User Code Location function, the lock will flash both the green and red LEDs and will emit 2
beeps.
•
The lock will identify the first digit by flashing the green LED and beeping 0 -9 times.
•
To signify the end of the first digit sequence, the lock will flash both the green and red LEDs and will emit 2 beeps.
•
The lock will identify the second digit by flashing the green LED and beeping 0 -9 times.
•
To signify the end of the Next Free User Code, the lock will flash both the green and red LEDs and will emit 2 beeps. If no
free address is found, then the lock will emit one long beep (0.5 sec) with a red LED.
Should a Free User Code ID not be found, the lock will sound one long beep (0.5 sec) with a red LED.
Reset to Factory Default Settings
Reset to Factory Default Settings with a Master Code
Key Sequence
[#] [Master Code] ● [99] ● [99] ●●
Reset to Factory Default Settings without a Master Code
1. Remove one battery.
2.
Press and hold the “0” button, then replace the battery.
3.
Release the “0” button after green LED flashes twice and lock beeps twice.
4. Within 3 seconds, press the star
✴
key 3 times.
•
The green LED will light for 7 seconds and 2 beeps will sound.
•
The lock is reset to the Factory Default Settings. All programming is deleted. Master Code is 12345.